conductivity versus air-exposure time
as-synthesised Ni-HATI-Me film · Thin Film
Conductivity monitored during exposure of films to ambient air.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Ni-HATI-Me initial conductivity increase on air exposure | about twice in the first 5 min | — | about | Text Approximate | p004 · Host-Guest Interaction-Modulated Thermoelectrics · Figure 2a |
| Ni-HAB/Ni-HATP/Ni-HATI-H conductivity after initial air exposure | reduced to 30-85% once (<5 min) exposed to ambient air | — | range 30-85% | Text Range | p004 · Host-Guest Interaction-Modulated Thermoelectrics · Figure 2a |