Electroluminescence measured by Shimadzu RF5310PC spectrofluorometer with voltage measured by voltmeter
ITO/NNU-27/ITO electroluminescent device · Electrode
ITO/NNU-27/ITO devices under ambient conditions; ITO cleaned in deionised water, ethanol and acetone for 30 min; connected by silver wires with 1000 Ohm tandem resistance.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| EL device thickness | larger than 100 um | — | — | Text Approximate | p004 · Electroluminescence |
| electroluminescence emission peakMarked as a best value within this paper | 575 nm | — | — | Text Exact Reported | p004 · Electroluminescence · Figure 3b |
| electroluminescence turn-on voltageMarked as a best value within this paper | about 27 (+/-3) V | — | +/-3 V | Text Rounded Reported | p004 · Electroluminescence · Figure 3a |
| device turn-on voltage range maximum | 30 V | — | — | Text Exact Reported | p004 · Electroluminescence · Figure 3a |
| device turn-on voltage range minimum | 24 V | — | — | Text Exact Reported | p004 · Electroluminescence · Figure 3a |