Spectroscopy — Multiple-Hydrogen-Bond Approach to Uncommon Pd(III) Oxidation State: A Pd-Br Chain with High Conductivity and Thermal Stability

Measurement evidence

Spectroscopy

Multiple-Hydrogen-Bond Approach to Uncommon Pd(III) Oxidation State: A Pd-Br Chain with High Conductivity and Thermal Stability · Mian M.R., Iguchi H., Takaishi S. et al. · Journal of the American Chemical Society · 2017 · 6562-6565

3 measurement groups · 6 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

ESR spectroscopy and spin susceptibility

Polycrystalline compound 3 · Powder

Bruker EMX spectrometer with Oxford ESR 900 gas-flow cryostat; susceptibility calibrated using CuSO4.5H2O standard.

Temperature
4-290
Geometry
polycrystalline sample
Context
pristine target material
Measurement source
SI p.S2 · Characterization and Instrumentation · Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
ESR g parallelg_parallel = 2.00162.0016Text
Exact Reported
main p.3, article p.6564 · ESR spectra · Figure S4
ESR g perpendicularg_perp = 2.12482.1248Text
Exact Reported
main p.3, article p.6564 · ESR spectra · Figure S4
Curie-like magnetic impurity fraction0.04% magnetic impurities below 60 K0.0004 fractionText
Exact Reported
main p.3, article p.6564 · ESR spectra · Figure S4

polarized reflectivity converted to optical conductivity by Kramers-Kronig transformation

Copper-luster rod-like single crystals of compound 3 · Single Crystal

UV-Vis-NIR reflectivity spectra recorded on a specially designed spectrometer with 25 cm grating monochromator and optical microscope.

Temperature
293
Context
pristine target crystal
Measurement source
SI p.S2 · Characterization and Instrumentation · Figure S5; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
optical band gap / lowest charge-transfer energyMarked as a best value within this paper0.45 eV0.45 eVText
Rounded Reported
main p.3, article p.6564 · Optical conductivity · Figure S5; Table S2
peak optical conductivity magnitudeabout 6900 S cm-1 near 0.45 eV6900 S cm-1visual estimate from Figure S5 axisVisual Estimate
Approximate
SI p.S8 · Optical conductivity spectrum of 3 · Figure S5

polarized Raman spectroscopy

Copper-luster rod-like single crystals of compound 3 · Single Crystal

Renishaw Raman spectrometer with He-Ne laser (632.8 nm); optical cryostat used below room temperature; spectra acquired from 10 to 300 K.

Temperature
10-300
Context
pristine target crystal
Measurement source
main p.2, article p.6563 · Raman confirmation of electronic state · Figure 2b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Br-Pd-Br symmetric stretching signal near 130 cm-1no signals observed around 130 cm-1 from 10 to 300 KText
Qualitative
main p.2, article p.6563 · Raman confirmation of electronic state · Figure 2b