Spectroscopy — Conjugated crosslinks boost the conductivity and stability of a single crystalline metal-organic framework

Measurement evidence

Spectroscopy

Conjugated crosslinks boost the conductivity and stability of a single crystalline metal-organic framework · Zhou H.-Q., He Y., Hu J.-Y. et al. · Chemical Communications · 2021 · 187-190

5 measurement groups · 6 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

diffuse reflectance / Kubelka-Munk bandgap estimate

activated ZrBPD-4F4TS-Ox · Powder

activated ZrBPD-4F4TS-Ox

Geometry
powder
Context
crosslinked framework
Measurement source
PDF p.4 / article p.189 · Main text · Fig. S37
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
optical bandgap~1.66 eVText
Approximate
PDF p.4 / article p.189 · Main text · Fig. S37

diffuse reflectance

H2BPD-4F4TS-p yellow polymer product · Powder

solution-polymerised H2BPD-4F4TS-p

Geometry
powder
Context
model polymer
Measurement source
SI p.S34 · Fig. S39 caption · Fig. S39
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
diffuse reflectance similarity to ZrBPD-4F4TS-Oxcompares well with ZrBPD-4F4TS-Ox spectrumCaption
Qualitative
SI p.S34 · Fig. S39 caption · Fig. S39

diffuse reflectance / Kubelka-Munk bandgap estimate

activated ZrBPD-4F4TS · Powder

activated ZrBPD-4F4TS

Geometry
powder
Context
pristine framework
Measurement source
PDF p.4 / article p.189 · Main text · Fig. S37
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
optical bandgap~2.75 eVText
Approximate
PDF p.4 / article p.189 · Main text · Fig. S37

FT-IR after HF/HCl treatment

activated ZrBPD-4F4TS-Ox · Powder

0.2% HF/0.36% HCl or 0.2% HF/1.8% HCl in DMSO at 85 deg C

Temperature
358
Geometry
powder
Context
crosslinked framework
Measurement source
SI p.S22 · Fig. S15 caption and note · Fig. S15
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
carboxylate stretch peak1607 cm-1 weakened after HF treatmentText
Exact Reported
SI p.S22 · Fig. S15 note · Fig. S15
free COOH stretch peak1711 cm-1 emergent/dominant after harsher acidText
Exact Reported
SI p.S22 · Fig. S15 note · Fig. S15

solid-state 13C NMR

activated ZrBPD-4F4TS-Ox · Powder

activated ZrBPD-4F4TS and activated ZrBPD-4F4TS-Ox comparison

Geometry
powder
Context
crosslinked vs pristine
Measurement source
PDF p.4 / article p.189 · Main text · Fig. S30
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
solid-state 13C NMR evidence for crosslinkingshoulder at ~136.0 ppm became more intense relative to main peak at ~127.5 ppmText
Approximate
PDF p.4 / article p.189 · Main text · Fig. S30