Electrochemistry Application — Nanoporous synthetic metal: A nickel MOF with an amino-functionalized macrocyclic ligand

Measurement evidence

Electrochemistry Application

Nanoporous synthetic metal: A nickel MOF with an amino-functionalized macrocyclic ligand · Pham H.T.B., Fang X., Choi J.Y. et al. · Chem · 2025 · 102487

4 measurement groups · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

cyclic voltammetry

Cu-HATC CV composite electrode ink · Electrode

MOF/Super P/PTFE on glassy carbon; Ag/Ag+ reference; Pt counter; 0.1 M TABF/acetonitrile; 100 mV/s

Geometry
three-electrode glassy-carbon working electrode
Context
composite electrode ink
Measurement source
S2 · Cyclic voltammetry measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
oxidation potential versus Ag/Ag+Eox = 0.02 V versus Ag/Ag+Figure Axis
Exact Reported
33 · Figure S42C · S42C
reduction potential versus Ag/Ag+Ered = -1.06 V versus Ag/Ag+Figure Axis
Exact Reported
33 · Figure S42C · S42C

cyclic voltammetry with ferrocene reference

Cu-HATC CV composite electrode ink · Electrode

Same CV electrode with Ferrocene reference

Geometry
three-electrode glassy-carbon working electrode
Context
composite electrode ink
Measurement source
S33 · Cyclic voltammetry · Figure S42D
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
reduction potential versus Fc/Fc+Ered = -1.19 V versus Fc/Fc+Figure Axis
Exact Reported
33 · Figure S42D · S42D

cyclic voltammetry

Ni-HATC CV composite electrode ink · Electrode

MOF/Super P/PTFE on glassy carbon; Ag/Ag+ reference; Pt counter; 0.1 M TABF/acetonitrile; 100 mV/s

Geometry
three-electrode glassy-carbon working electrode
Context
composite electrode ink
Measurement source
S2 · Cyclic voltammetry measurements
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
reduction potential versus Ag/Ag+Ered = -1.08 V versus Ag/Ag+Figure Axis
Exact Reported
33 · Figure S42A · S42A

cyclic voltammetry with ferrocene reference

Ni-HATC CV composite electrode ink · Electrode

Same CV electrode with Ferrocene reference

Geometry
three-electrode glassy-carbon working electrode
Context
composite electrode ink
Measurement source
S33 · Cyclic voltammetry · Figure S42B
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
reduction potential versus Fc/Fc+Ered = -1.21 V versus Fc/Fc+Figure Axis
Exact Reported
33 · Figure S42B · S42B