solid-electrode cyclic voltammetry
Al-MOF solid-electrode CV composite · Electrode
Three-electrode Bio-Logic setup; GC working electrode composite; Ag/AgCl saturated KCl reference; graphite counter; 1 M H2SO4; 10 mV/s; 0.9-0 V vs Ag/AgCl for Al-MOF.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Reduction peak R1 | 0.55 +/- 0.01 V vs Ag/AgCl | 0.55 V vs Ag/AgCl | +/- 0.01 V | Text Exact Reported | p008 · Reversible redox behavior · Figure 5C |
| Reduction peak R2 | 0.38 V vs Ag/AgCl | 0.38 V vs Ag/AgCl | — | Text Exact Reported | p008 · Reversible redox behavior · Figure 5C |
| Reduction peak R3 | 0.195 +/- 0.005 V vs Ag/AgCl | 0.195 V vs Ag/AgCl | +/- 0.005 V | Text Exact Reported | p008 · Reversible redox behavior · Figure 5C |