Electrical Transport — Porous, conductive metal-triazolates and their structural elucidation by the charge-flipping method

Measurement evidence

Electrical Transport

Porous, conductive metal-triazolates and their structural elucidation by the charge-flipping method · Gandara F., Uribe-Romo F.J., Britt D.K. et al. · Chemistry - A European Journal · 2012 · 10595-10601

3 measurement groups · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Four-point probe DC conductivity after iodine-vapour exposure

MET-3 pellet exposed to iodine vapour · Pellet

Same pressed MET-3 pellet/device type after 40 min exposure to I2 vapour; PXRD checked after exposure.

Temperature
295
Atmosphere
vacuum measurement after I2 vapour exposure
Geometry
pressed pellet four-probe geometry
Context
iodine-doped MET-3 pellet; framework retained by PXRD
Measurement source
p.5, article p.10599 · Electrical conductivity · Figure 6b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
conductivity after I2 exposureMarked as a best value within this paper1.0 x 10^-3 S cm^-1 after 40 min I2 exposureText
Exact Reported
p.5, article p.10599 · Electrical conductivity · Figure 6b
iodine exposure conductivity enhancementca. 13-fold relative to pristine pelletCalculated From Reported
Approximate
p.5, article p.10599 · Electrical conductivity · Figure 6a-b

Four-point probe DC conductivity/resistivity measurement

MET-3 freshly prepared pressed pellet · Pellet

Pressed bulk pellet; 500 micrometre gold electrodes thermally deposited by shadow mask; 1.6 mm electrode spacing; Lake Shore TTP4 station under vacuum.

Temperature
295
Atmosphere
vacuum
Geometry
pressed pellet, 1 cm diameter, 0.5 mm thick; four-probe geometry
Context
pristine MET-3 framework pellet
Measurement source
p.5, article p.10599 · Electrical conductivity · Figure 6a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
undoped pellet conductivity stabilityconductivity does not degrade after eight weeks in airText
Exact Reported
p.5, article p.10599 · Electrical conductivity
room-temperature conductivityMarked as a best value within this paper0.77 x 10^-4 S cm^-1Text
Exact Reported
p.5, article p.10599 · Electrical conductivity · Figure 6a

Temperature-dependent four-point probe I-V curves

MET-3 freshly prepared pressed pellet · Pellet

Four-probe measurements at 295, 305, 315 and 325 K on MET-3 pellet under vacuum.

Temperature
295, 305, 315, 325
Atmosphere
vacuum
Geometry
pressed pellet four-probe geometry
Context
pristine MET-3 framework pellet
Measurement source
p.5, article p.10599 · Electrical conductivity · Figure 6d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
temperature dependence of current/conductivityconductivity/current increases with temperature from 295 to 325 KCaption
Qualitative
p.5, article p.10599 · Electrical conductivity · Figure 6d