Electrical Transport — From insulator to semiconductor: effect of host-guest interactions on charge transport in M-MOF-74 metal-organic frameworks

Measurement evidence

Electrical Transport

From insulator to semiconductor: effect of host-guest interactions on charge transport in M-MOF-74 metal-organic frameworks · Angel S.M., Barnett N.S., Talin A.A. et al. · Journal of Materials Chemistry C · 2024 · 2699-2704

8 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

IV/conductivity control measurement

H4TCNQ@Cu-MOF-74 pellet · Pellet

Room-temperature IV curve for H4TCNQ@Cu-MOF-74.

Temperature
room temperature
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
Hydrogenated guest control.
Measurement source
S-9 · Conductivity Data · Fig. S6c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H4TCNQ@Cu-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Text
Qualitative
S-9 · Conductivity Data · Fig. S6

IV/conductivity control measurement

H4TCNQ@Mg-MOF-74 pellet · Pellet

Room-temperature IV curve for H4TCNQ@Mg-MOF-74.

Temperature
room temperature
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
Hydrogenated guest closed-shell control.
Measurement source
S-9 · Conductivity Data · Fig. S6a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H4TCNQ@Mg-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Caption
Qualitative
S-9 · Conductivity Data · Fig. S5

IV/conductivity control measurement

H4TCNQ@Mn-MOF-74 pellet · Pellet

Room-temperature IV curve for H4TCNQ@Mn-MOF-74.

Temperature
room temperature
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
Hydrogenated guest control.
Measurement source
S-9 · Conductivity Data · Fig. S6d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H4TCNQ@Mn-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Text
Qualitative
S-9 · Conductivity Data · Fig. S5

IV/conductivity control measurement

H4TCNQ@Zn-MOF-74 pellet · Pellet

Room-temperature IV curve for H4TCNQ@Zn-MOF-74.

Temperature
room temperature
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
Hydrogenated guest closed-shell control.
Measurement source
S-9 · Conductivity Data · Fig. S6b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H4TCNQ@Zn-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Caption
Qualitative
S-9 · Conductivity Data · Fig. S5

Temperature-dependent two-point probe electrical transport

TCNQ@Cu-MOF-74 pellet · Pellet

Argon-filled glovebox (<1 ppm O2) using Gamry PCI4750-333041 potentiostat; powder pressed into pellet with 3 tons force for 2 min using 50 mg material, 0.5 mm thickness; measured 294-353 K.

Temperature
294-353
Atmosphere
argon glovebox, <1 ppm O2
Geometry
Two-point probe pellet with large-area electrodes.
Context
TCNQ-loaded conductive Cu-MOF-74.
Measurement source
S-6 · Characterization methods · Fig. S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Activation energy for TCNQ@Cu-MOF-74Activation energy 889.9 meV.0.8899 eVText
Exact Reported
2701 · Results and discussion · Fig. 3c
Maximum conductivity of TCNQ@Cu-MOF-74Marked as a best value within this paperConductivity increased up to 5.40 x 10^-2 S m^-1 from 294 K to 353 K.0.00054 S cm-1Text
Exact Reported
2701 · Results and discussion · Fig. 3
Approximate TCNQ@Cu-MOF-74 current at 353 K and +1 VApprox. +1.0 microampere at +1 V for the 353 K trace.0.000001 Avisual estimate from plotted axisFigure Axis
Approximate
2701 · Figure · Fig. 3a

IV/conductivity control measurement

TCNQ@Mg-MOF-74 pellet · Pellet

Room-temperature IV curves shown in Fig. S5; main text also states no detectable conductivity as temperature increased.

Temperature
room temperature; temperature-dependent check reported qualitatively
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
TCNQ-loaded Mg-MOF-74 control.
Measurement source
S-9 · Conductivity Data · Fig. S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
TCNQ@Mg-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Caption
Qualitative
S-9 · Conductivity Data · Fig. S5

Temperature-dependent two-point probe electrical transport

TCNQ@Mn-MOF-74 pellet · Pellet

Same pellet/probe method as Cu; measured 294-353 K.

Temperature
294-353
Atmosphere
argon glovebox, <1 ppm O2
Geometry
Two-point probe pellet with large-area electrodes.
Context
TCNQ-loaded conductive Mn-MOF-74.
Measurement source
2700-2701 · Results and discussion · Fig. 3b,d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Activation energy for TCNQ@Mn-MOF-74Activation energy 580.7 meV.0.5807 eVText
Exact Reported
2701 · Results and discussion · Fig. 3d
Maximum conductivity of TCNQ@Mn-MOF-74Conductivity increased up to 5.02 x 10^-3 S m^-1 from 294 K to 353 K.0.0000502 S cm-1Text
Exact Reported
2701 · Results and discussion · Fig. 3
Approximate TCNQ@Mn-MOF-74 current at 353 K and +1 VApprox. +0.16 microampere at +1 V for the 353 K trace.1.6e-7 Avisual estimate from plotted axisFigure Axis
Approximate
2701 · Figure · Fig. 3b

IV/conductivity control measurement

TCNQ@Zn-MOF-74 pellet · Pellet

Room-temperature IV curves shown in Fig. S5; main text also states no detectable conductivity as temperature increased.

Temperature
room temperature; temperature-dependent check reported qualitatively
Atmosphere
argon glovebox, <1 ppm O2 for conductivity method
Geometry
Pressed pellet two-point probe.
Context
TCNQ-loaded Zn-MOF-74 control.
Measurement source
S-9 · Conductivity Data · Fig. S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
TCNQ@Zn-MOF-74 conductivityNo detectable/practically zero conductivity reported.Detection limit not reported.Caption
Qualitative
S-9 · Conductivity Data · Fig. S5