cyclic voltammetry and ECL intensity-time response

ZnCoMOFs black precipitate/powder · Powder

HHTP and ZnCoMOFs compared in the presence of potassium persulfate

Context
pristine ZnCoMOFs compared with HHTP control
Measurement source
4 · 3.3. Electrochemical and ECL characterization of ZnCoMOFs · Fig. 3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
HHTP CV minimum reduction currentabout -1.5 x 10^-3 AFigure Axis
Approximate
4 · 3.3 · Fig. 3A
ZnCoMOFs CV minimum reduction currentMarked as a best value within this paperabout -1.8 x 10^-3 AFigure Axis
Approximate
4 · 3.3 · Fig. 3A
HHTP ECL peak intensityabout 0.75k a.u.visual estimateFigure Axis
Approximate
4 · 3.3 · Fig. 3B
ZnCoMOFs CV reduction current vs HHTPMarked as a best value within this papermore pronounced reduction current than HHTPText
Qualitative
4 · 3.3 · Fig. 3A
ZnCoMOFs ECL peak intensityMarked as a best value within this paperabout 3.0k a.u.visual estimateFigure Axis
Approximate
4 · 3.3 · Fig. 3B

CV and electrochemical impedance spectroscopy (EIS)

AFB1/BSA/Ab/Au NPs/ZnCoMOFs/GCE · Electrode

Layer-by-layer sensor construction assessed for ZnCoMOFs/GCE, Au NPs/ZnCoMOFs/GCE, Ab/Au NPs/ZnCoMOFs/GCE, BSA/Ab/Au NPs/ZnCoMOFs/GCE, and AFB1/BSA/Ab/Au NPs/ZnCoMOFs/GCE

Geometry
modified glassy carbon electrodes
Context
composite sensor with pristine ZnCoMOFs component
Measurement source
5 · 3.4. Characterization of sensor bonding process · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Au NPs/ZnCoMOFs/GCE apparent EIS semicircle widthMarked as a best value within this paperabout 0.9 kOhmFigure Axis
Approximate
4 · 3.4 · Fig. 4B
AFB1/BSA/Ab/Au NPs/ZnCoMOFs/GCE apparent EIS semicircle widthabout 9.4 kOhmFigure Axis
Approximate
4 · 3.4 · Fig. 4B
ZnCoMOFs/GCE apparent EIS semicircle widthabout 1.7 kOhmFigure Axis
Approximate
4 · 3.4 · Fig. 4B
Au NPs effect on CV peak currentAu NPs/ZnCoMOFs/GCE has greater peak current than ZnCoMOFs/GCEText
Qualitative
5 · 3.4 · Fig. 4A
Biomolecule-layer effect on CV currentAb, BSA, and AFB1 layers gradually decrease peak currentText
Qualitative
5 · 3.4 · Fig. 4A
Au NPs effect on charge-transfer resistancecharge-transfer resistance reduced after Au NPs modificationText
Qualitative
5 · 3.4 · Fig. 4B