Sensing Application — Sensing interface based on electrodeposited Cu-BTC microporous film for electrochemical detection of the painkiller paracetamol

Measurement evidence

Sensing Application

Sensing interface based on electrodeposited Cu-BTC microporous film for electrochemical detection of the painkiller paracetamol · Tien Dat N., Ngoc Tien N., Ngan N.T.T. et al. · Analyst · 2023 · 1777-1785

9 measurement groups · 20 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

square wave voltammetry calibration

Bare GCE · Electrode

SWV paracetamol calibration in the same 10-50 uM range as Cu-BTC/GCE.

Geometry
bare GCE electrode
Context
bare substrate control
Measurement source
p007 / 1783 · 3.5 Paracetamol detection · Table 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
linear concentration range10-50 uMTable
Range
p007 / 1783 · 3.5 · Table 2
paracetamol limit of detection0.2030 uMTable
Exact Reported
p007 / 1783 · 3.5 · Table 2
paracetamol sensitivity0.481 uA uM-1 cm-2Table
Exact Reported
p007 / 1783 · 3.5 · Table 2

square wave voltammetry calibration

Cu-BTC/GCE, optimised 5 min film · Electrode

SWV in potential range +200 to +700 mV; paracetamol concentration 10-50 uM for calibration.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p007 / 1783 · 3.5 Paracetamol detection · Fig. 7; Table 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
SWV calibration equationMarked as a best value within this paperI (uA) = 0.0697 C (uM) - 0.1868; R2 = 0.9977Text
Rounded Reported
p007 / 1783 · 3.5 · Fig. 7
linear concentration rangeMarked as a best value within this paper10-50 uMTable
Range
p007 / 1783 · 3.5 · Table 2
paracetamol limit of detectionMarked as a best value within this paper0.0770 uMTable
Exact Reported
p007 / 1783 · 3.5 · Table 2
paracetamol sensitivityMarked as a best value within this paper0.996 uA uM-1 cm-2Table
Exact Reported
p007 / 1783 · 3.5 · Table 2

cyclic voltammetry for paracetamol oxidation

Bare GCE · Electrode

1 mM paracetamol in PBS buffer at pH 7.4, scan rate 50 mV s-1.

Geometry
bare GCE electrode
Context
bare substrate control
Measurement source
p005-p006 / 1781-1782 · 3.4 Oxidation of paracetamol · Fig. 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
paracetamol pseudo-reversible peak separation642 mVText
Exact Reported
p005 / 1781 · 3.4 · Fig. 6

cyclic voltammetry for paracetamol oxidation

Cu-BTC/GCE, optimised 5 min film · Electrode

1 mM paracetamol in PBS buffer at pH 7.4, scan rate 50 mV s-1.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p005-p006 / 1781-1782 · 3.4 Oxidation of paracetamol · Fig. 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
current intensity improvement in paracetamol CV15%Text
Rounded Reported
p005 / 1781 · 3.4 · Fig. 6
paracetamol pseudo-reversible peak separationMarked as a best value within this paper88 mVText
Exact Reported
p005 / 1781 · 3.4 · Fig. 6
reported thermodynamic energy for paracetamol oxidationDelta G = 245.91 kcal mol-1Text
Exact Reported
p005 / 1781 · 3.4 · Scheme 2

CV/SWV pH dependence for paracetamol oxidation

Cu-BTC/GCE, optimised 5 min film · Electrode

1 mM paracetamol solutions at pH 5 to 9; SI Fig. 5S compares Cu-BTC/GCE and GCE.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p007 / 1783 · 3.4 Oxidation of paracetamol · Fig. 5S
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Epa(pH) slope-0.0468Text
Exact Reported
p007 / 1783 · 3.4 · Fig. 5S
optimal pH for paracetamol oxidationMarked as a best value within this paperneutral pHneutral; pH 7.4 also included in measurementsText
Approximate
p007 / 1783 · 3.4 · Fig. 5S

real-sample SWV assay

Cu-BTC/GCE, optimised 5 min film · Electrode

1 mg traditional painkiller powder dissolved in 10 mL PBS buffer; SWV recorded on Cu-BTC/GCE.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p007 / 1783 · 3.5 Paracetamol detection
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
paracetamol content in traditional painkiller26.9 mg g-1Text
Exact Reported
p007 / 1783 · 3.5

reproducibility by SWV currents from five identically fabricated electrodes

Cu-BTC/GCE, optimised 5 min film · Electrode

Five Cu-BTC/GCE sensors analysed under identical SWV conditions.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p007 / 1783 · 3.5 Paracetamol detection
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
sensor reproducibility RSDMarked as a best value within this paper1.6%Text
Exact Reported
p007 / 1783 · 3.5

scan-rate dependence of paracetamol oxidation

Cu-BTC/GCE, optimised 5 min film · Electrode

Scan rates from 10 to 200 mV s-1; SI Fig. 6S.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p007 / 1783 · 3.4 Oxidation of paracetamol · Fig. 6S
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
scan-rate dependence mechanismanodic and cathodic currents proportional to square root of scan rate; diffusion-based processText
Qualitative
p007 / 1783 · 3.4 · Fig. 6
scan-rate range10 to 200 mV s-1Text
Range
p007 / 1783 · 3.4 · Fig. 6S

SWV calibration versus synthesis time

Cu-BTC/GCE, 15 min film · Electrode

SI Fig. 8S compares GCE, Cu-BTC 5 minutes and Cu-BTC 15 minutes for paracetamol calibration.

Geometry
Cu-BTC/GCE electrode
Context
pristine Cu-BTC film sensor
Measurement source
p005 · SI · Fig. 8S
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
15 min Cu-BTC calibration R-square0.99691SI Table
Exact Reported
p005 · SI · Fig. 8S
15 min Cu-BTC calibration slope0.07478 +/- 0.0017 uA uM-1+/- 0.0017 uA uM-1SI Table
Exact Reported
p005 · SI · Fig. 8S
effect of increasing synthesis timeno significant improvement in recorded signalsText
Qualitative
p007 / 1783 · 3.5 · Fig. 8S