Spectroscopy — Sensing interface based on electrodeposited Cu-BTC microporous film for electrochemical detection of the painkiller paracetamol

Measurement evidence

Spectroscopy

Sensing interface based on electrodeposited Cu-BTC microporous film for electrochemical detection of the painkiller paracetamol · Tien Dat N., Ngoc Tien N., Ngan N.T.T. et al. · Analyst · 2023 · 1777-1785

2 measurement groups · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

ATR-FTIR spectroscopy

Cu-BTC/GCE, optimised 5 min film · Electrode

FTIR spectrum of Cu-BTC grown on GCE, recorded on Nicolet iS50 Thermo Fisher spectrometer.

Geometry
film on GCE
Context
pristine Cu-BTC film
Measurement source
p004 / 1780 · 3.2 Morphology and structure studies · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
FTIR assigned peaks1585 cm-1 asymmetric carboxylate, 1321 cm-1 symmetric carboxylate, 700 cm-1 metal-oxygen, 1038 cm-1 C-O-CuText
Rounded Reported
p004 / 1780 · 3.2 · Fig. 4

Raman spectroscopy

Cu-BTC/GCE, optimised 5 min film · Electrode

Raman spectrum of Cu-BTC grown on GCE, recorded on Labram Horiba spectrometer.

Geometry
film on GCE
Context
pristine Cu-BTC film
Measurement source
p004 / 1780 · 3.2 Morphology and structure studies · Fig. 3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Raman assigned peaks742 and 827 cm-1 (-CH), 1006 cm-1 C=C, 1548 and 1458 cm-1 O-C-O, 500 cm-1 Cu-OText
Rounded Reported
p004 / 1780 · 3.2 · Fig. 3