Sensing Application — Two-Dimensional Conjugated Metal-Organic Frameworks with Large Pore Apertures and High Surface Areas for NO2 Selective Chemiresistive Sensing

Measurement evidence

Sensing Application

Two-Dimensional Conjugated Metal-Organic Frameworks with Large Pore Apertures and High Surface Areas for NO2 Selective Chemiresistive Sensing · Chen P., Su X., Wang C. et al. · Angewandte Chemie - International Edition · 2023 · e202306224

3 measurement groups · 17 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Chemiresistive NO2 sensing controls

Ni3(HIB)2 chemiresistive sensing device · Electrode

Room-temperature response of Ni3(HIB)2 and Ni3(HITP)2 toward 100 ppm NO2.

Temperature
298
Atmosphere
NO2 in air
Geometry
not separately specified
Context
pristine smaller-pore 2D c-MOF controls
Measurement source
S18-S20 · Chemiresistive Sensing · Figures S33-S34 / Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni3(HIB)2 response to 100 ppm NO2138%SI Table
Exact Reported
S20 · Table S3 · Table S3
Ni3(HIB)2 response time to 100 ppm NO22.44 minSI Table
Exact Reported
S20 · Table S3 · Table S3
Ni3(HITP)2 response to 100 ppm NO271%SI Table
Exact Reported
S20 · Table S3 · Table S3
Ni3(HITP)2 response time to 100 ppm NO22.25 minSI Table
Exact Reported
S20 · Table S3 · Table S3

Chemiresistive gas sensing

HIOTP-Cu chemiresistive sensing device · Electrode

Room temperature gas sensing on HIOTP-Cu device, including 100 ppm NO2 response.

Temperature
298
Atmosphere
dry synthetic air with NO2 or VOC analytes
Geometry
interdigital electrode, 100 um gaps
Context
pristine HIOTP-Cu active layer
Measurement source
S17 · Chemiresistive Sensing · Figures S30-S31
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
HIOTP-Cu response to 100 ppm NO2Marked as a best value within this paper55.6%Figure Axis
Approximate
S17 · Chemiresistive Sensing · Figure S30
HIOTP-Cu recovery time after 100 ppm NO2Marked as a best value within this papertrec = 1.24 minFigure Axis
Approximate
S17 · Chemiresistive Sensing · Figure S31
HIOTP-Cu response time to 100 ppm NO2Marked as a best value within this papertres = 0.51 minFigure Axis
Approximate
S17 · Chemiresistive Sensing · Figure S31

Chemiresistive NO2 sensing

HIOTP-Ni chemiresistive sensing device · Electrode

Room temperature, dark, dry synthetic air purge, 5 V bias, 600 sccm gas flow; response defined as Ig/I0 - 1.

Temperature
298
Atmosphere
dry synthetic air with NO2 or VOC analytes
Geometry
interdigital electrode, 100 um gaps
Context
pristine HIOTP-Ni active layer
Measurement source
S3 / S20 · Gas sensor characterization; Chemiresistive Sensing · Figure 3 / Table S3
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
HIOTP-Ni crystal structure after NO2 sensingPXRD preserved after sensingText
Qualitative
p004 · Long-term stability · Figures S35-S36
HIOTP-Ni theoretical NO2 limit of detectionMarked as a best value within this paper0.21 ppm (Table S3 rounds to 0.2 ppm)Text
Exact Reported
p004 · NO2 sensing · Figure 3d / Tables S3-S4
HIOTP-Ni log-log response-concentration linearityR2 = 0.98 over 1-100 ppmText
Exact Reported
p003-p004 · NO2 sensing · Figure 3d
HIOTP-Ni 10 ppm NO2 repeatability coefficient of variation1.3%Text
Exact Reported
p003 · NO2 sensing · Figure 3c
HIOTP-Ni response to 100 ppm NO2Marked as a best value within this paper2416%SI Table
Exact Reported
S20 · Table S3 · Table S3 / Figure 3a
HIOTP-Ni response to 10 ppm NO2Marked as a best value within this paper405%SI Table
Exact Reported
S20 · Chemiresistive Sensing · Table S3
HIOTP-Ni recovery time after 100 ppm NO255.42 minSI Table
Exact Reported
S20 · Table S3 · Table S3
HIOTP-Ni recovery time after 10 ppm NO210.32 minSI Table
Exact Reported
S20 · Table S3 · Table S3
HIOTP-Ni response time to 100 ppm NO21.88 minSI Table
Exact Reported
S20 · Table S3 · Table S3
HIOTP-Ni response time to 10 ppm NO2Marked as a best value within this paper1.69 minSI Table
Exact Reported
S20 · Table S3 · Table S3