Two-probe I-V conductivity with Keithley 2400 source meter / semiconductor analyser
Cu(I)-TPT tablet for I-V conductivity · Pellet
Linear I-V sweep from -2 to 2 V under ambient conditions; dark, 300 W xenon irradiation, and xenon irradiation with ethanol sacrificial donor.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Electronic conductivity under dark conditions | 1.28 x 10^-11 S cm-1 | 1.28e-9 S m-1 | — | Text Exact Reported | p003 / 20659 · Characterizations · Figure S8 |
| Electronic conductivity under 300 W xenon irradiation | 1.4 x 10^-11 S cm-1 | 1.4e-9 S m-1 | — | Text Exact Reported | p003 / 20659 · Characterizations · Figure S8 |
| Electronic conductivity under xenon irradiation with ethanolMarked as a best value within this paper | 2 x 10^-7 S cm-1 | 0.00002 S m-1 | — | Text Rounded Reported | p004 / 20660 · Characterizations · Figure 4f |