Electrochemistry Application — Synthesis and characterization of Fe3O4-supported metal–organic framework MIL-101(Fe) for a highly selective and sensitive hydrogen peroxide electrochemical sensor

Measurement evidence

Electrochemistry Application

Synthesis and characterization of Fe3O4-supported metal–organic framework MIL-101(Fe) for a highly selective and sensitive hydrogen peroxide electrochemical sensor · Salman F., Zengin A., Celik Kazici H. · Ionics · 2020 · 5221-5232

4 measurement groups · 8 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Cyclic voltammetry

MIL-101(Fe)@Fe3O4/NGCE sensor · Electrode

H2O2 0-55 mM in N2-saturated 0.1 M PBS, pH 7; scan rate 50 mV s-1

Atmosphere
N2-saturated
Geometry
modified NGCE working electrode
Context
target sensor versus bare NGCE control
Measurement source
5224-5226 · Electrochemical properties · Fig. 4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Bare NGCE H2O2 reduction responsequite weak compared with MIL-101(Fe)@Fe3O4/NGCEQualitative
Qualitative
5224 · Electrochemical properties · Fig. 4
Anodic peak current at 55 mM H2O2200 uAText
Rounded Reported
5225 · Electrochemical properties · Fig. 4
Cathodic peak current at 55 mM H2O2386 uAText
Rounded Reported
5225 · Electrochemical properties · Fig. 4

Randles-Sevcik electroactive surface area

MIL-101(Fe)@Fe3O4/NGCE sensor · Electrode

K3[Fe(CN)6] redox system measured by CV at varied scan rates

Geometry
modified NGCE working electrode
Context
target sensor
Measurement source
5226 · Electrochemical properties · Eq. 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Electroactive surface area0.56 cm2Calculated From Reported
Exact Reported
5226 · Electrochemical properties · Eq. 6
Geometric area of GCE0.0707 cm2Text
Exact Reported
5226 · Electrochemical properties

Cyclic voltammetry pH study

MIL-101(Fe)@Fe3O4/NGCE sensor · Electrode

10 mM H2O2 in N2-saturated 0.1 M PBS; pH 4-9; scan rate 50 mV s-1

Atmosphere
N2-saturated
Geometry
modified NGCE working electrode
Context
target sensor
Measurement source
5225-5227 · Electrochemical properties · Fig. 6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Optimum pHMarked as a best value within this paperpH 9.0Text
Exact Reported
5226-5227 · Electrochemical properties · Fig. 6

Cyclic voltammetry scan-rate study

MIL-101(Fe)@Fe3O4/NGCE sensor · Electrode

5 mM H2O2 in PBS pH 7.0; scan rates 10-100 mV s-1

Geometry
modified NGCE working electrode
Context
target sensor
Measurement source
5225-5226 · Electrochemical properties · Fig. 5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Anodic peak-current scan-rate regression slopeI_anodic (mA) = 0.0074 v(mV/s)-0.0209; R2 = 0.99R2 = 0.99Text
Exact Reported
5225 · Electrochemical properties · Eq. 4
Cathodic peak-current scan-rate regression slopeI_cathodic (mA) = -0.0153 v(mV/s)-0.0009; R2 = 0.99R2 = 0.99Text
Exact Reported
5225 · Electrochemical properties · Eq. 5