Chronoamperometry
MIL-101(Fe)@Fe3O4/NGCE sensor · Electrode
H2O2 successive injections in stirred 0.1 M PBS pH 9 at -0.5 V versus Ag/AgCl
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CA linear detection range | 0.005-0.02 mM (5-20 uM) | — | — | Table Range | 5228-5229 · Analytical application · Table 2 |
| CA limit of detection | 1.76 uM | — | — | Table Exact Reported | 5228-5229 · Analytical application · Table 2 |
| CA peak-current measured concentration upper value | up to 55 uM | — | — | Text Rounded Reported | 5228 · Analytical application · Fig. 8 |
| CA calibration slope | Ip = 0.3092 C_H2O2 + 12.363; SD = 0.183; R2 = 0.99 | — | SD = 0.183; R2 = 0.99 | Text Exact Reported | 5228 · Analytical application · Fig. 8 |
| CA sensitivityMarked as a best value within this paper | 556.5037 uA mM-1 cm-2 | — | — | Table Exact Reported | 5228-5229 · Analytical application · Table 2 |