Microscopy Morphology — Missing-Linker 2D Conductive Metal Organic Frameworks for Rapid Gas Detection

Measurement evidence

Microscopy Morphology

Missing-Linker 2D Conductive Metal Organic Frameworks for Rapid Gas Detection · Liu C., Gu Y., Liu C. et al. · ACS Sensors · 2021 · 429-438

1 measurement group · 1 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

SEM; Hitachi S-4800 / JEOL JEM-1011 noted in SI

aNi-HAB chemiresistive device · Electrode

As-prepared aNi-HAB film deposited between gold electrodes; samples on carbon tapes/glue for general SEM.

Geometry
film between Au electrodes on Si chip
Context
pristine target device
Measurement source
430-432 · Figure 1 caption; Relative humidity detection · Figure 1e; Figure S3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
aNi-HAB film morphologyclosely packed in a thin film on the silicon waferText
Qualitative
432 · Relative humidity detection · Figure 1e