room-temperature NH3 chemiresistive sensing
~80 nm edge-on Cu3(HHTP)2 NH3 sensor · Thin Film
2.5-50 ppm NH3 in N2 carrier, 500 sccm total flow, 100 mV bias
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Freundlich K parameter | 17.229 | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| Freundlich b parameter | 0.476 | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| pseudo-first-order rate constant | 5.492 min-1 | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| theoretical limit of detection | 0.319 ppm | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| kinetic fit R2 | 0.998 | — | — | Text Exact Reported | 17063 · Results and Discussion · Figure S36d |
| NH3 response at 30 ppm | 90% | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| NH3 response at 50 ppm | 111% | — | — | SI Table Exact Reported | 40 · Gas Sensing · Table S2 |
| NH3 recovery time at 30 ppm | 857 s | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| NH3 response time at 30 ppm | 69 s | — | — | Text Exact Reported | 17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2 |
| NH3 response time at 50 ppm | 0.87 min | — | — | SI Table Exact Reported | 40 · Gas Sensing · Table S2 |