Sensing Application — Catalysis-Assisted Synthesis of Two-Dimensional Conductive Metal–Organic Framework Films with Controllable Orientation

Measurement evidence

Sensing Application

Catalysis-Assisted Synthesis of Two-Dimensional Conductive Metal–Organic Framework Films with Controllable Orientation · Song M., Wu Y., Jia J. et al. · Journal of the American Chemical Society · 2025 · 17058-17067

2 measurement groups · 25 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

room-temperature NH3 chemiresistive sensing

~80 nm edge-on Cu3(HHTP)2 NH3 sensor · Thin Film

2.5-50 ppm NH3 in N2 carrier, 500 sccm total flow, 100 mV bias

Temperature
298
Atmosphere
N2 carrier
Geometry
interfinger Au electrodes
Context
pristine conductive MOF film
Measurement source
17063-17064 · Results and Discussion · Figure S36; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Freundlich K parameter17.229Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
Freundlich b parameter0.476Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
pseudo-first-order rate constant5.492 min-1Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
theoretical limit of detection0.319 ppmText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
kinetic fit R20.998Text
Exact Reported
17063 · Results and Discussion · Figure S36d
NH3 response at 30 ppm90%Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response at 50 ppm111%SI Table
Exact Reported
40 · Gas Sensing · Table S2
NH3 recovery time at 30 ppm857 sText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response time at 30 ppm69 sText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response time at 50 ppm0.87 minSI Table
Exact Reported
40 · Gas Sensing · Table S2

room-temperature NH3 chemiresistive sensing

~70 nm face-on Cu3(HHTP)2 NH3 sensor · Thin Film

2.5-50 ppm NH3 in N2 carrier, 500 sccm total flow, 100 mV bias

Temperature
298
Atmosphere
N2 carrier
Geometry
interfinger Au electrodes
Context
pristine conductive MOF film
Measurement source
17063-17064 · Results and Discussion · Figure 8; Figure S35; Table S2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Freundlich K parameterMarked as a best value within this paper30.944Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
Freundlich b parameterMarked as a best value within this paper0.552Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
pseudo-first-order rate constantMarked as a best value within this paper9.368 min-1Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
theoretical limit of detectionMarked as a best value within this paper0.129 ppmText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
kinetic fit R20.997Text
Exact Reported
17063 · Results and Discussion · Figure 8c
tested NH3 concentration range2.5-50 ppmCaption
Range
17063 · Results and Discussion · Figure 8d
NH3 response at 30 ppmMarked as a best value within this paper197%Text
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response at 50 ppmMarked as a best value within this paper262%SI Table
Exact Reported
40 · Gas Sensing · Table S2
NH3 recovery time at 30 ppm208 sText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response time at 30 ppmMarked as a best value within this paper27 sText
Exact Reported
17063-17064 · Results and Discussion · Figure 8; Figure S36; Table S2
NH3 response time at 50 ppmMarked as a best value within this paper0.37 minSI Table
Exact Reported
40 · Gas Sensing · Table S2
acetone response at 30 ppm1.83%Text
Exact Reported
17064 · Results and Discussion · Figure S37
ethanol response at 30 ppm2.64%Text
Exact Reported
17064 · Results and Discussion · Figure S37
H2O response at 30 ppm0.61%Text
Exact Reported
17064 · Results and Discussion · Figure S37
methanol response at 30 ppm1.26%Text
Exact Reported
17064 · Results and Discussion · Figure S37