Electrochemistry Application — Electrochemical immunoassay for the carcinoembryonic antigen based on Au NPs modified zeolitic imidazolate framework and ordered mesoporous carbon

Measurement evidence

Electrochemistry Application

Electrochemical immunoassay for the carcinoembryonic antigen based on Au NPs modified zeolitic imidazolate framework and ordered mesoporous carbon · Zhang Y., Zhang Z., Rong S. et al. · Microchimica Acta · 2020 · 264

3 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

cyclic voltammetry

Au NPs@ZIF-8/OMC/GCE · Electrode

CV in 0.1 M KCl containing 5 mM Fe(CN)6(3-/4-) at 50 mV s-1, comparing Au@ZIF-8/OMC/GCE, bare GCE, Au@ZIF-8/GCE, ZIF-8/GCE, anti-CEA/Au@ZIF-8/OMC/GCE and CEA/anti-CEA/Au@ZIF-8/OMC/GCE.

Geometry
Three-electrode cell with modified GCE working electrode, SCE reference, Pt plate auxiliary.
Context
Composite platform compared with pristine ZIF-8 and electrode controls.
Measurement source
4-5 · Characteristics of different electrodes · Fig. 4a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Au@ZIF-8/OMC/GCE anodic peak potential0.307 VText
Exact Reported
5 · Characteristics of different electrodes · Fig. 4a
Au@ZIF-8/OMC/GCE cathodic peak potential0.234 VText
Exact Reported
5 · Characteristics of different electrodes · Fig. 4a
Au@ZIF-8/OMC/GCE peak-to-peak separationaround 73 mVText
Approximate
5 · Characteristics of different electrodes · Fig. 4a
OMC enhances electrochemical currentMarked as a best value within this paperAu NPs@ZIF-8/OMC/GCE peak current larger than Au NPs@ZIF-8/GCEText
Qualitative
4 · Characteristics of different electrodes · Fig. 4a
ZIF-8 decreases electrode peak currentpeak current obviously decreased after ZIF-8 was dropped on an electrode, ascribed to nonconducting properties of ZIF-8Text
Qualitative
4 · Characteristics of different electrodes · Fig. 4a

differential pulse voltammetry

Au NPs@ZIF-8/OMC/GCE · Electrode

DPV current change (Delta I_DPV) for 100 ng mL-1 CEA using electrodes modified by ZIF-8, Au@ZIF-8, OMC, ZIF-8/OMC and Au@ZIF-8/OMC in 0.1 M KCl containing 5 mM Fe(CN)6(3-/4-), n = 3.

Geometry
Modified GCE electrodes.
Context
Material-component comparison including pristine ZIF-8 control.
Measurement source
5-6 · Characteristics of different electrodes · Fig. 4c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
DPV current change for Au@ZIF-8 electrodeapproximately 1.4 x 10-5 AVisual Estimate
Approximate
5 · Characteristics of different electrodes · Fig. 4c
DPV current change for Au@ZIF-8/OMC electrodeMarked as a best value within this paperapproximately 2.7 x 10-5 AVisual Estimate
Approximate
6 · Characteristics of different electrodes · Fig. 4c
DPV current change for OMC electrodeapproximately 0.7 x 10-5 AVisual Estimate
Approximate
5 · Characteristics of different electrodes · Fig. 4c
DPV current change for ZIF-8 electrodeapproximately 0.85 x 10-5 AVisual Estimate
Approximate
5 · Characteristics of different electrodes · Fig. 4c
DPV current change for ZIF-8/OMC electrodeapproximately 1.6 x 10-5 AVisual Estimate
Approximate
5 · Characteristics of different electrodes · Fig. 4c

electrochemical impedance spectroscopy

Au NPs@ZIF-8/OMC/GCE · Electrode

EIS measured from 100 kHz to 1 Hz with signal amplitude of 5 mV for electrode modification series.

Geometry
Three-electrode cell with modified GCE working electrode, SCE reference, Pt plate auxiliary.
Context
Au@ZIF-8/OMC/GCE compared against ZIF-8/GCE, Au@ZIF-8/GCE, bare GCE and biofunctionalised electrodes.
Measurement source
5-6 · Characteristics of different electrodes · Fig. 4b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Au@ZIF-8 lowers electron-transfer resistance vs ZIF-8Au@ZIF-8 modified GCE presented smaller electron transfer resistance than ZIF-8 modified GCEText
Qualitative
5 · Characteristics of different electrodes · Fig. 4b
Protein and immunocomplex layers increase electron-transfer resistanceimmobilization of antibody and combination between CEA and anti-CEA lead to increased electron transfer resistanceText
Qualitative
6 · Characteristics of different electrodes · Fig. 4b