Sensing Application — Facile one-pot synthesis of Co coordination polymer spheres doped macroporous carbon and its application for electrocatalytic oxidation of glucose

Measurement evidence

Sensing Application

Facile one-pot synthesis of Co coordination polymer spheres doped macroporous carbon and its application for electrocatalytic oxidation of glucose · Meng T., Shang N., Zhao J. et al. · Journal of Colloid and Interface Science · 2021 · 135-146

5 measurement groups · 24 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Amperometric i-t measurement

Co CPSs/MPC-2-GCE · Electrode

Continuous glucose additions at +0.45 to +0.70 V for MPC, Co CPSs and Co CPSs/MPC-2.

Geometry
modified GCE
Context
pristine controls and target composite
Measurement source
141-142 · 3.2 · Fig. 8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Optimised working potential for Co CPSs+0.65 VText
Exact Reported
141 · 3.2 · Fig. 8C-D
Optimised working potential for Co CPSs/MPC-2Marked as a best value within this paper+0.65 VText
Exact Reported
141 · 3.2 · Fig. 8E-F
Optimised working potential for MPC+0.55 VText
Exact Reported
141 · 3.2 · Fig. 8A-B

Amperometric calibration for glucose detection

Co CPSs/MPC-2-GCE · Electrode

Successive glucose addition at optimal potential; MPC at +0.55 V, Co CPSs and Co CPSs/MPC-2 at +0.65 V.

Geometry
modified GCE
Context
controls and target composite
Measurement source
141-144 · 3.2 · Fig. 9; Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Co CPSs/MPC-2 high-range calibration slopeY = 1.1162 x 10^-5 + 0.04812 XFigure Axis
Exact Reported
143 · Figure · Fig. 9F
Co CPSs/MPC-2 low-range calibration slopeMarked as a best value within this paperY = 7.0356 x 10^-6 + 0.06863 XFigure Axis
Exact Reported
143 · Figure · Fig. 9F
Linear range, Co CPSs-GCE1-830 uMText
Range
141 · 3.2 · Fig. 9D
Linear range, Co CPSs/MPC-2-GCE high rangeMarked as a best value within this paper0.158-1.58 mM in Table 1; text states 0.158-1.36 mMTable
Range
144 · Table 1 · Table 1
Linear range, Co CPSs/MPC-2-GCE low rangeMarked as a best value within this paper0.0005-0.158 mMText
Range
141 · 3.2 · Fig. 9F; Table 1
Linear range, MPC-GCE75-1500 uMText
Range
141 · 3.2 · Fig. 9B
Limit of detection, Co CPSs-GCE0.26 uM (S/N = 3)Text
Exact Reported
141 · 3.2 · Fig. 9D
Limit of detection, Co CPSs/MPC-2-GCEMarked as a best value within this paper0.084 uM (S/N = 3)Text
Exact Reported
141-144 · 3.2; Table 1 · Fig. 9F; Table 1
Limit of detection, MPC-GCE8.4 uM (S/N = 3)Text
Exact Reported
141 · 3.2 · Fig. 9B
Glucose response time, Co CPSs-GCE2.64 sFigure Axis
Exact Reported
143 · Figure · Fig. 9C inset
Glucose response time, Co CPSs/MPC-2-GCEMarked as a best value within this paper1.713 sText
Exact Reported
141 · 3.2 · Fig. 9E inset
Glucose response time, MPC-GCE4.28 sFigure Axis
Exact Reported
143 · Figure · Fig. 9A inset

Interference/selectivity amperometry

Co CPSs/MPC-2-GCE · Electrode

Glucose response compared with 5 uM L-phenylalanine, D-tyrosine, L-arginine, D-cysteine, glycine, L-tryptophan, L-ascorbic acid and L-tyrosine in 0.1 M NaOH.

Geometry
Co CPSs/MPC-2-GCE
Context
target composite
Measurement source
141-144 · 3.2 · Fig. 10; Fig. S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Selectivity against amino-acid and ascorbic-acid interferentsMarked as a best value within this paperinterferences have negligible response compared with glucoseQualitative
Qualitative
141-144 · 3.2 · Fig. 10; Fig. S6

Human serum spike-recovery glucose determination

Co CPSs/MPC-2-GCE · Electrode

Three human serum samples spiked with 5 or 10 uM glucose; n = 10.

Geometry
Co CPSs/MPC-2-GCE
Context
target composite
Measurement source
142-144 · 3.2 · Table 2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Serum sample a recovery at 10 uM added glucose97.54%RSD 4.00%Table
Exact Reported
144 · Table 2 · Table 2
Serum sample a recovery at 5 uM added glucose97.48%RSD 5.30%Table
Exact Reported
144 · Table 2 · Table 2
Serum sample b recovery at 10 uM added glucose92.5%RSD 1.2%Table
Exact Reported
144 · Table 2 · Table 2
Serum sample b recovery at 5 uM added glucose97.6%RSD 2.3%Table
Exact Reported
144 · Table 2 · Table 2
Serum sample c recovery at 10 uM added glucoseMarked as a best value within this paper100.84%RSD 3.8%Table
Exact Reported
144 · Table 2 · Table 2
Serum sample c recovery at 5 uM added glucose95.34%RSD 1.9%Table
Exact Reported
144 · Table 2 · Table 2

Storage stability and repeatability testing

Co CPSs/MPC-2-GCE · Electrode

Current response to 0.05 mM glucose after storage at 4 deg C for 14 days; repeatability tested 10 times.

Temperature
277.15
Geometry
Co CPSs/MPC-2-GCE
Context
target composite
Measurement source
141 · 3.2
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Repeatability RSD5.68%Text
Exact Reported
141 · 3.2
Response retention after 14 daysMarked as a best value within this paper97.5% of initial responseText
Exact Reported
141 · 3.2