Single-crystal conductivity by clamping individual crystals between circular gold relay contacts and measuring resistance with a voltmeter.
Hand-picked TUB75 crystals · Single Crystal
Room-temperature measurements; flat side of crystal between 1 mm diameter gold contacts; approximate 1 mm2 flat contact area; crystal orientation varied relative to gold surfaces.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| maximum approximate conductivityMarked as a best value within this paper | ~10^3 S m-1 | 1000 S m-1 | — | Calculated From Reported Approximate | 4 · Electrical conductivity measurements |
| minimum approximate conductivity | ~10^-3 S m-1 | 0.001 S m-1 | — | Calculated From Reported Approximate | 4 · Electrical conductivity measurements |
| resistance change after heating | reduced resistance after heating to 130 C | — | — | Qualitative Qualitative | 4 · Electrical conductivity measurements |
| maximum measured resistance | ~10 Mohm | — | — | Text Approximate | 4 · Electrical conductivity measurements |
| minimum measured resistance | ~10 ohm | — | — | Text Approximate | 4 · Electrical conductivity measurements |