Other — Self-Powered Disinfection Using Triboelectric, Conductive Wires of Metal-Organic Frameworks

Measurement evidence

Other

Self-Powered Disinfection Using Triboelectric, Conductive Wires of Metal-Organic Frameworks · Huo Z.-Y., Yang Y., Jeong J.-M. et al. · Nano Letters · 2023 · 3090-3097

1 measurement group · 4 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

pH and conductivity measurements for real water samples

Cu-HHTP NW-Cu electrode · Electrode

River water from Qing He River and tap water from Renmin University of China.

Context
Input water for disinfection application measurements
Measurement source
SI p020 · Tables · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
river water conductivity0.17 mS cm^-1SI Table
Exact Reported
SI p020 · Tables · Table S1
river water pH7.2SI Table
Exact Reported
SI p020 · Tables · Table S1
tap water conductivity0.05 mS cm^-1SI Table
Exact Reported
SI p020 · Tables · Table S1
tap water pH6.8SI Table
Exact Reported
SI p020 · Tables · Table S1