Spectroscopy — Self-Powered Disinfection Using Triboelectric, Conductive Wires of Metal-Organic Frameworks

Measurement evidence

Spectroscopy

Self-Powered Disinfection Using Triboelectric, Conductive Wires of Metal-Organic Frameworks · Huo Z.-Y., Yang Y., Jeong J.-M. et al. · Nano Letters · 2023 · 3090-3097

1 measurement group · 5 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

X-ray photoelectron spectroscopy

Cu-HHTP NW-Cu electrode · Electrode

Cu 2p XPS and SI broad scan for Cu-HHTP NW-Cu electrode.

Geometry
Cu-HHTP NW-Cu electrode
Context
Composite electrode
Measurement source
3093 · Results · Figure 2g; Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XPS broad-scan elementsCu 2p, O 1s, C 1s presentCaption
Qualitative
SI p010 · Figures · Figure S4
Cu 2p peak932.20 eVText
Exact Reported
3093 · Results · Figure 2g
Cu 2p peak934.42 eVText
Exact Reported
3093 · Results · Figure 2g
Cu satellite peak952.06 eVText
Exact Reported
3093 · Results · Figure 2g
Cu satellite peak954.12 eVText
Exact Reported
3093 · Results · Figure 2g