UV-vis and emission spectroscopy of ligand and metallopolymer solutions
poly-Fe-L2 isolated metallopolymer powder · Powder
MeOH, c = 15 microM; electronic absorption and emission spectra
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| MLCT extinction coefficient for poly-Fe-L1 | 3.4 x 10^4 M-1 cm-1 | — | — | Text Rounded Reported | p004 · Synthesis and Characterization · Figure 2a-c |
| MLCT extinction coefficient for poly-Fe-L2 | 3.4 x 10^4 M-1 cm-1 | — | — | Text Rounded Reported | p004 · Synthesis and Characterization · Figure 2a-c |
| MLCT extinction coefficient for poly-Fe-L3Marked as a best value within this paper | 5.1 x 10^4 M-1 cm-1 | — | — | Text Rounded Reported | p004 · Synthesis and Characterization · Figure 2a-c |
| MLCT absorption maximum for poly-Fe-L1 | 570 nm | — | — | Figure Axis Rounded Reported | p003 · Synthesis and Characterization · Figure 2a |
| MLCT absorption maximum for poly-Fe-L2 | 572 nm | — | — | Figure Axis Rounded Reported | p003 · Synthesis and Characterization · Figure 2b |
| MLCT absorption maximum for poly-Fe-L3 | 574 nm | — | — | Figure Axis Rounded Reported | p003 · Synthesis and Characterization · Figure 2c |