Other — Multifunctional coordination polymers based on copper with modified nucleobases, easily modulated in size and conductivity

Measurement evidence

Other

Multifunctional coordination polymers based on copper with modified nucleobases, easily modulated in size and conductivity · Vegas V.G., Maldonado N., Castillo O. et al. · Journal of Inorganic Biochemistry · 2019 · 110805

3 measurement groups · 10 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

SQUID magnetic susceptibility and magnetisation

CP1 polycrystalline/powder sample · Powder

2-300 K susceptibility at 0.5 T on 9.440 mg polycrystalline CP1; isothermal magnetisation -5 to 5 T at 2 K.

Temperature
2-300
Context
pristine polycrystalline CP1
Measurement source
2 · Materials and methods
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Temperature of rounded chi_m maximumca. 220 Kca.Text
Approximate
4 · 3.2. Magnetic properties · Fig. 5b
CP1 low-temperature chi_m T plateauclose to 0.1 cm3 K mol^-1 below ca. 50 Kbelow ca. 50 KText
Approximate
4 · 3.2. Magnetic properties · Fig. 5a
CP1 room-temperature chi_m Tca. 0.6 cm3 K mol^-1Text
Approximate
4 · 3.2. Magnetic properties · Fig. 5a
Bleaney-Bowers fit g valueg = 2.215Text
Exact Reported
4 · 3.2. Magnetic properties · Fig. 5b
Monomeric Cu(II) impurity in magnetic fit13.5%Text
Exact Reported
4 · 3.2. Magnetic properties · Fig. 5b
Bleaney-Bowers exchange parameter JJ = -293 cm^-1Text
Exact Reported
4 · 3.2. Magnetic properties · Fig. 5b

Thermogravimetric analysis with evolved gas analysis

CP1 polycrystalline/powder sample · Powder

N2 purge 90 mL/min; room temperature to 650 deg C at 5 deg C/min using Pt sample holder.

Atmosphere
N2
Context
pristine CP1 powder
Measurement source
2 · Materials and methods
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
CP1 higher-temperature decomposition range140-650 deg CText
Range
SI text · Figure S2 caption/commentary · Figure S2
CP1 observed first-stage mass lossobserved 4.3%Text
Rounded Reported
SI text · Figure S2 caption/commentary · Figure S2
CP1 first TGA mass-loss temperaturefirst stage at 135 deg CText
Rounded Reported
SI text · Figure S2 caption/commentary · Figure S2

Thermogravimetric analysis with evolved gas ion-current monitoring

CP1 previously dehydrated to 140 deg C · Powder

CP1 previously dehydrated to 140 deg C, then analysed by TGA/MS; compared with non-dehydrated CP1.

Atmosphere
N2
Context
dehydrated CP1 powder
Measurement source
6 · Figure S2 caption/commentary · Figure S2b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Dehydrated CP1 lacks 135 deg C water signalno water (m/z=18) at 135 deg C after heat treatment at 140 deg CText
Qualitative