Cyclic voltammetry for double-layer capacitance (Cdl)
Co3O4 control catalyst ink on conductive carbon paper · Electrode
CVs recorded at scan rates from 25 to 200 mV s-1 to estimate electrochemically active surface area.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| double-layer capacitance | 6.0 x 10-3 mF cm-2 | 0.006 mF cm-2 | — | Text Exact Reported | 6 · Result and discussion · Figure 7c |