Other — Efficient oxygen evolution using conductive cobalt-based metal-organic framework

Measurement evidence

Other

Efficient oxygen evolution using conductive cobalt-based metal-organic framework · Suliman M.H., Tawfiq Alfuhaid L., Khan A. et al. · Fuel · 2024 · 131044

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Thermogravimetric analysis (TGA)

as-synthesised Co-BTB MOF powder · Powder

Activated Co-BTB sample heated in alumina pan under airflow to 800 deg C; main text says 5 deg C min-1, SI says 10 deg C min-1.

Atmosphere
air / airflow
Geometry
alumina pan
Context
activated pristine framework powder
Measurement source
SI text · Materials and General Methods
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
TGA framework decomposition mass loss43% around 300 deg Caround 300 deg CText
Rounded Reported
3 · Result and discussion · Figure 3b
TGA retained water/solvent mass loss10% between 150 and 200 deg Ctemperature interval 150-200 deg CText
Rounded Reported
3 · Result and discussion · Figure 3b
TGA residual mass47% residueText
Rounded Reported
3 · Result and discussion · Figure 3b