Electrical Transport — High-Performance H2S Sensors to Detect SF6 Leakage

Measurement evidence

Electrical Transport

High-Performance H2S Sensors to Detect SF6 Leakage · Zhao X., Jiang S., Zhang Z. et al. · ACS Sensors · 2024 · 5512-5519

3 measurement groups · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

four-point probe conductivity

Co1.8Ni1.2(HITP)2 powder · Powder

Resistance measured with source meter and converted to conductivity.

Geometry
four-point probe on sample; Figure S5 schematic
Context
pristine mixed-metal powder
Measurement source
3 · 2.1. Sample Preparation and Characterization · Figure S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivityMarked as a best value within this paper1970 S m-1Text
Exact Reported
3 · 2.1. Sample Preparation and Characterization

four-point probe conductivity

Co3(HITP)2 powder · Powder

Resistance measured with source meter and converted to conductivity.

Geometry
four-point probe on sample; Figure S5 schematic
Context
pristine monometallic control powder
Measurement source
3 · Conductivity measurement · Figure S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivity654 S m-1Text
Exact Reported
3 · 2.1. Sample Preparation and Characterization

four-point probe conductivity

Ni3(HITP)2 powder · Powder

Resistance measured with source meter and converted to conductivity using sigma = L/(R*A).

Geometry
four-point probe on sample; Figure S5 schematic
Context
pristine monometallic control powder
Measurement source
3 · Conductivity measurement · Figure S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
electrical conductivity930 S m-1Text
Exact Reported
3 · 2.1. Sample Preparation and Characterization