Other — NiPd mediated by conductive metal organic frameworks with facilitated electron transfer for assaying of H2O2 released from living cells

Measurement evidence

Other

NiPd mediated by conductive metal organic frameworks with facilitated electron transfer for assaying of H2O2 released from living cells · Chen Z., Qian Y., Zhang L. et al. · Journal of Electroanalytical Chemistry · 2022 · 115985

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Water contact angle

NiPd@Ni3HHTP2/GC · Electrode

Contact angles of Ni3HHTP2/GC, NiPd/GC and NiPd@Ni3HHTP2/GC at ambient temperature.

Atmosphere
ambient
Geometry
modified GC electrodes
Context
target composite compared with controls
Measurement source
4 · 3.2. Electrochemical characterization of different modified electrodes · Fig. S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Contact angle of Ni3HHTP2/GCMarked as a best value within this paper9.4 +/- 1.2 deg+/- 1.2 degText
Exact Reported
4 · 3.2. Electrochemical characterization of different modified electrodes · Fig. S5
Contact angle of NiPd/GC19.69 +/- 2.3 deg+/- 2.3 degText
Exact Reported
4 · 3.2. Electrochemical characterization of different modified electrodes · Fig. S5
Contact angle of NiPd@Ni3HHTP2/GC12.2 +/- 1.8 deg+/- 1.8 degText
Exact Reported
4 · 3.2. Electrochemical characterization of different modified electrodes · Fig. S5