Thermogravimetric analysis (TGA)
Hydrothermal Cu3(HHTP)2 powder · Powder
Libra Netzsch instrument, air atmosphere, 50 mL min-1 flow, 10 C min-1 ramp
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CuO residue after TGA in air | 29.5% | — | — | Text Exact Reported | 6 · Hydrothermal synthesis of bulk Cu3(HHTP)2 · Figure 2b |
| First TGA mass loss | 12.85% from 30 to 120 C | — | — | Text Exact Reported | 6 · Hydrothermal synthesis of bulk Cu3(HHTP)2 · Figure 2b |
| Thermal decomposition onset | 230 C | 503.15 K | — | Text Exact Reported | 6 · Hydrothermal synthesis of bulk Cu3(HHTP)2 · Figure 2b |
| Second TGA mass loss | 70.5% with onset temperature 230 C | — | — | Text Exact Reported | 6 · Hydrothermal synthesis of bulk Cu3(HHTP)2 · Figure 2b |