Diffraction Structure — Enhancing Electrical Conductivity of Semiconducting MOFs via Defect Healing

Measurement evidence

Diffraction Structure

Enhancing Electrical Conductivity of Semiconducting MOFs via Defect Healing · Choi J.Y., Park J. · ACS Applied Electronic Materials · 2021 · 4197-4202

3 measurement groups · 12 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Synchrotron PXRD Pawley fit comparison for pristine Cu3(HAB)2 and HAB-treated MOF

HAB-treated Cu3(HAB)2, 30 min · Pellet

lambda = 0.45237 Angstrom; Table S1 reports crystal system, space group, lattice parameters and Rw

Context
pristine Cu3(HAB)2 compared with HAB-treated Cu3(HAB)2
Measurement source
S4 · Synchrotron PXRD Data · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Pawley a parameter for pristine Cu3(HAB)213.16364 AngstromSI Table
Exact Reported
S4 · Table S1
Pawley c parameter for pristine Cu3(HAB)23.18917 AngstromSI Table
Exact Reported
S4 · Table S1
Pawley Rw for pristine Cu3(HAB)24.265SI Table
Exact Reported
S4 · Table S1
Pawley a parameter for HAB-treated Cu3(HAB)213.15487 AngstromSI Table
Exact Reported
S4 · Table S1
Pawley c parameter for HAB-treated Cu3(HAB)23.1767 AngstromSI Table
Exact Reported
S4 · Table S1
Pawley Rw for HAB-treated Cu3(HAB)27.701SI Table
Exact Reported
S4 · Table S1

PXRD crystallinity comparison

TATHB-treated Cu3(TATHB)2 · Pellet

Postsynthetic treatment of Cu3(TATHB)2 and Co3(HAB)2 analogues; Figure S11 cited.

Context
treated analogue samples versus pristine analogues
Measurement source
5 · Results and Discussion · Figure S11 cited
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
analogue crystallinity enhancementsame trend of crystallinity enhancement in both casesText
Qualitative
5 · Results and Discussion · Figure S11 cited

Synchrotron PXRD and laboratory PXRD; Pawley fit; FWHM from [010]/[100] diffraction peak

HAB-treated Cu3(HAB)2, 30 min · Pellet

Synchrotron PXRD at beamline 17-BM, lambda = 0.45237 Angstrom; lab PXRD lambda = 0.71 Angstrom.

Context
treated sample compared against pristine Cu3(HAB)2
Measurement source
3 · Results and Discussion · Figure 2a,b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
crystallinity index after HAB treatmentMarked as a best value within this paper80%Text
Exact Reported
3 · Results and Discussion · Figure S2 cited
crystallinity index before HAB treatment69%Text
Exact Reported
3 · Results and Discussion · Figure S2 cited
PXRD FWHM after HAB treatmentMarked as a best value within this paper0.69 degText
Exact Reported
3 · Results and Discussion · Figure 2b
PXRD FWHM before HAB treatment0.8 degText
Rounded Reported
3 · Results and Discussion · Figure 2b
crystalline structure after treatmentgood agreement with previously reported 2D honeycomb-eclipsed structureText
Qualitative
3 · Results and Discussion · Figure 2a; Figure S3; Table S1