CV and UV-vis-derived HOMO/LUMO/band-gap estimates
NiCB@NU-1000 powder · Powder
CV of NiCB and TBAPy solutions converted to NHE by adding 0.21 V; UV-vis absorption used for TBAPy band gap; NU-1000 values from previous electrochemically addressable thin-film and diffuse-reflectance estimates.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Band gap of NU-1000 | 2.57 eV | — | — | SI Table Exact Reported | S8 · S2 · Table S1 |
| Band gap of TBAPy linker | 2.92 eV | — | — | SI Table Exact Reported | S8 · S2 · Table S1 |
| HOMO of NU-1000 | 1.43 E vs NHE | — | — | SI Table Exact Reported | S8 · S2 · Table S1 |
| HOMO of TBAPy linker | 1.23 E vs NHE | — | — | SI Table Exact Reported | S8 · S2 · Table S1 |
| LUMO of NiCB | 0.57 E vs NHE | — | — | SI Table Exact Reported | S8 · S2 · Table S1 |