Spectroscopy — In-Plane Oriented Two-Dimensional Conjugated Metal-Organic Framework Films for High-Performance Humidity Sensing

Measurement evidence

Spectroscopy

In-Plane Oriented Two-Dimensional Conjugated Metal-Organic Framework Films for High-Performance Humidity Sensing · Park S., Zhang Z., Qi H. et al. · ACS Materials Letters · 2022 · 1146-1153

3 measurement groups · 10 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

XPS

HAB-Cu intermediate without SDS · Powder

High-resolution Cu 2p and N 1s of HAB-Cu intermediate.

Context
HAB-Cu model intermediate
Measurement source
1149 · Results · Figure 4a-b; Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
HAB-Cu Cu(I) XPS peak932 eVText
Rounded Reported
1149 · Results · Figure 4a
HAB-Cu Cu(II) XPS peak935 eVText
Rounded Reported
1149 · Results · Figure 4a
HAB-Cu interlayer distance by HRTEM~9.2 AText
Approximate
1149 · Results · Figure S10
HAB-Cu C-NH+ to C-NH2 ratio1:50.2 C-NH+/C-NH2Text
Exact Reported
1149 · Results · Figure 4b
HAB-Cu Cu(II):Cu(I) ratio1:11 Cu(II)/Cu(I)Text
Exact Reported
1149 · Results · Figure 4a

ex-situ Raman spectroscopy under N2 and H2O/N2 gas streams

HIB-Cu film chemiresistive humidity sensor · Electrode

561 nm excitation; gas mixture guided into small PE-foil-sealed chamber.

Atmosphere
N2 and H2O/N2
Geometry
HIB-Cu film in gas-stream Raman chamber
Context
pristine HIB-Cu film exposed to humidity
Measurement source
1151 · Results · Figure 5e
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu-N chelate Raman responseno observable change near ~450 cm-1Text
Qualitative
1151 · Results · Figure 5e
linker Raman band shift after H2O exposure~15 cm-1 shift to higher frequency for bands at 1510 and 1550 cm-1Text
Approximate
1151 · Results · Figure 5e

X-ray photoelectron spectroscopy (XPS)

free-standing in-plane oriented HIB-Cu film · Thin Film

High-resolution Cu 2p and N 1s spectra; PHI-5000C ESCA system.

Temperature
room temperature
Context
pristine HIB-Cu film
Measurement source
1148 · Results · Figure S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Cu 2p3/2 binding energy in final HIB-Cu film935 eVText
Rounded Reported
1148 · Results · Figure S1
charge-balancing ions in final HIB-CuNa+ or Cl- not detected; neutral stateQualitative
Qualitative
1148 · Results · Figure S1
Cu satellite peak in final HIB-Cu film943 eVText
Rounded Reported
1148 · Results · Figure S1