Circularly polarised visible photodetection
CAS-4 thin film-based Au photodetector · Electrode
UV-Vis detector photoelectric testing system with Keithley 2636b; LCP/RCP generated with LBTEK LCP25-VIS-M and RCP25-VIS-M plates; 10 V bias; 600 nm and wavelength-dependent tests.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| CNN recognition rate for LCP/RCP images | 0.99 after approximately 30 training epochs | 99 % | — | Text Approximate | main p.7, article p.26680 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure 5e |
| Maximum detectivity under LCPMarked as a best value within this paper | 1.58 x 10^11 Jones | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure 4h |
| Maximum detectivity under RCP | 8.48 x 10^10 Jones | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure 4h |
| Maximum EQE under LCPMarked as a best value within this paper | 186% | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure S20b |
| Maximum EQE under RCP | 98% | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure S20b |
| Maximum photocurrent anisotropy factor gIphMarked as a best value within this paper | 0.51 at 10 V | — | — | Text Rounded Reported | main p.5, article p.26678 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure 4e |
| Peak responsivity under 600 nm LCPMarked as a best value within this paper | 0.90 A/W | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure S20a; Figure 4b |
| Peak responsivity under 600 nm RCP | 0.52 A/W | — | — | Text Rounded Reported | main p.6, article p.26679 · CP Photodetection Performance of CAS-4 MOF Thin Film · Figure S20a; Figure 4b |
| Photocurrent used in chiral MOF comparison table | 1.25 uA | — | — | SI Table Rounded Reported | SI Table S3 in text layer after Figure S41 · Table S3 · Table S3 |
| gIph for 10-cycle film | approximately 0.35 | — | bar shown; roughly +/-0.02 | Visual Estimate Approximate | SI p.28 · Results and Discussions · Figure S27 |
| gIph for 15-cycle film | approximately 0.43 | — | bar shown; roughly +/-0.02 | Visual Estimate Approximate | SI p.28 · Results and Discussions · Figure S27 |
| gIph for 20-cycle filmMarked as a best value within this paper | approximately 0.51 | — | bar shown; roughly +/-0.02 | Visual Estimate Approximate | SI p.28 · Results and Discussions · Figure S27 |
| gIph for 25-cycle film | approximately 0.48 | — | bar shown; roughly +/-0.02 | Visual Estimate Approximate | SI p.28 · Results and Discussions · Figure S27 |
| gIph for 5-cycle film | approximately 0.29 | — | bar shown; roughly +/-0.02 | Visual Estimate Approximate | SI p.28 · Results and Discussions · Figure S27 |