Two-electrode pellet conductivity by I-V current scan
Cu3(HHTP)2 air-synthesis particles · Powder
Packed pellets in PEEK 2-electrode screw cell; 7-10 mg powder; 0.56 Nm torque; settled before current scan.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| pellet conductivity replicate 1 | 2e-02 S/cm | — | — | SI Table Rounded Reported | S15 · Supplementary Tables · Table S7 |
| pellet conductivity replicate 2 | 3e-02 S/cm | — | — | SI Table Rounded Reported | S15 · Supplementary Tables · Table S7 |
| pellet conductivity replicate 3 | 9e-03 S/cm | — | — | SI Table Rounded Reported | S15 · Supplementary Tables · Table S7 |
| mean pellet conductivity (calculated)Marked as a best value within this paper | 0.0197 S/cm | — | — | Calculated From Reported Approximate | S15 · Supplementary Tables · Table S7 |