TGA and DSC
ZnBTA MOF glass detector · Electrode
Supplementary thermal analysis for ZnBTA; TGA from 25 to 500 C under N2 and DSC beginning from 30 C under N2 flow.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| ZnBTA melting temperature from DSC label | Tm = 98 C | — | — | Figure Axis Rounded Reported | SI p.S9 · Supplementary Figures · Figure S5d |