Two-probe direct-current electrical conductivity
CP1 pressed pellet · Pellet
Pressed pellet measured at 295 K after pressing at 6.0 GPa for 2 min; voltages from -10.0 to +10.0 V.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Pressed-pellet electrical conductivity at 295 K | xbar = 1.1 x 10^-7 S/cm | — | — | Visual Estimate Rounded Reported | SI p.16 · S6 Electrical behaviour study · Fig. S20 |