Spectroscopy — Multi-stimulus semiconductor Cu(i)-I-pyrimidine coordination polymer with thermo- and mechanochromic sensing

Measurement evidence

Spectroscopy

Multi-stimulus semiconductor Cu(i)-I-pyrimidine coordination polymer with thermo- and mechanochromic sensing · Lopez J., Murillo M., Lifante-Pedrola G. et al. · CrystEngComm · 2022 · 341-349

3 measurement groups · 11 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Diffuse reflectance UV-visible spectroscopy

CP1 precipitated bulk solid / polycrystalline powder · Powder

Diffuse reflectance spectrum of CP1 compared with aClpym ligand over roughly 300-1200 nm.

Geometry
Not specified in text layer.
Context
pristine CP1 powder
Measurement source
SI p.17 · S8 Diffuse reflectance UV-visible spectroscopy · Fig. S23
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Diffuse reflectance spectrum reportedCP1 diffuse-reflectance spectrum reported versus ligand from about 300 to 1200 nm; no band gap value stated.Caption
Qualitative
SI p.17 · S8 Diffuse reflectance UV-visible spectroscopy · Fig. S23

ATR-FTIR

CP1 precipitated bulk solid / polycrystalline powder · Powder

PerkinElmer 100 spectrophotometer with universal ATR; 4000 to 650 cm^-1.

Geometry
ATR sampling accessory.
Context
pristine CP1 powder
Measurement source
main p.2 / article p.342 · Materials and methods · Fig. S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Selected strong ATR-IR band1478 cm^-1 (vs)Text
Exact Reported
main p.3 / article p.343 · Synthetic procedure · Fig. S6

Temporal luminescence decay

CP1 precipitated bulk solid / polycrystalline powder · Powder

Emission decay recorded at 300 K and 80 K under excitation at 355 nm using the third harmonic of a pulsed Nd:YAG laser; double-exponential fits.

Temperature
300; 80
Geometry
Pulsed Nd:YAG laser excitation.
Context
pristine CP1 powder
Measurement source
main p.5 / article p.345 · Photophysical properties · Fig. S10; Table S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
A1/(A1+A2) at 300 K0.92SI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
A1/(A1+A2) at 80 K0.84SI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
Average lifetime at 300 K0.03 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
Average lifetime at 80 K0.11 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
Room-temperature emission wavelength in lifetime table470 nm at 300 KSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
tau1 at 300 K0.02 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
tau1 at 80 K0.03 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
tau2 at 300 K0.08 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6
tau2 at 80 K0.18 usSI Table
Exact Reported
SI p.10 · S4 Emission studies · Table S6