Electrochemistry Application — Electrically Conductive Metal–Organic Framework Thin Film-Based On-Chip Micro-Biosensor: A Platform to Unravel Surface Morphology-Dependent Biosensing

Measurement evidence

Electrochemistry Application

Electrically Conductive Metal–Organic Framework Thin Film-Based On-Chip Micro-Biosensor: A Platform to Unravel Surface Morphology-Dependent Biosensing · Chen X., Dong J., Chi K. et al. · Advanced Functional Materials · 2021 · 2102855

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Scan-rate-dependent cyclic voltammetry

BS-Cu-BHT film on on-chip electrode · Electrode

BS-Cu-BHT film in 0.2 mM H2O2 at scan rates of 10, 25, 50, 75, and 100 mV s-1 in 0.1 M PBS; reduction peak current density plotted versus square root of scan rate.

Geometry
on-chip micro-biosensor
Context
pristine BS-Cu-BHT film device
Measurement source
p009 · Supporting Information · Figure S14
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Scan-rate square-root fit slopeIp = -21.26 v^1/2 + 14.49, R2 = 0.989R2 = 0.989Figure Axis
Rounded Reported
p009 · Supporting Information · Figure S14b
Reduction peak current relation to square root of scan ratelinearly proportional in 10 to 100 mV s-1Text
Qualitative
p009 · Supporting Information · Figure S14