Electrical Transport — NH2-UiO-66 Metal-Organic Framework Nanoparticles for Hydroxide Ion Conductive Photoswitches

Measurement evidence

Electrical Transport

NH2-UiO-66 Metal-Organic Framework Nanoparticles for Hydroxide Ion Conductive Photoswitches · Wang S., Fan S., Fang Z. et al. · ACS Applied Nano Materials · 2021 · 8352-8359

13 measurement groups · 35 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

AC impedance conductivity versus temperature; Arrhenius-like fit

NH2-UiO-66-10-OH · Pellet

Hydroxide ion activation energy at 95% RH.

Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p003 · Results · Figure 2d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hydroxide-ion activation energy0.59 eV0.59 eVText
Exact Reported
p003 · Results · Figure 2d

AC impedance conductivity versus temperature; Arrhenius-like fit

NH2-UiO-66-50-OH · Pellet

Hydroxide ion activation energy for NH2-UiO-66-50-OH at 95% RH.

Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p002 · Additional figures · Figure S2c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hydroxide-ion activation energy0.54 eV0.54 eVFigure Axis
Rounded Reported
p002 · Additional figures · Figure S2c

AC impedance hydroxide ion conductivity

NH2-UiO-66-0-OH · Pellet

Light on/off cycles at 55 deg C, 95% RH; visible light intensity 50 mW cm^-2.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet; cross-section 100 um x 3 mm; transport distance 300 um
Context
OH-loaded MOF pellet
Measurement source
p004-p006 · Results; Methods · Figure 3a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hydroxide conductivity, light off~8 x 10^-7 S cm^-10.00008 S m^-1Visual Estimate
Approximate
p004 · Results · Figure 3a; Figure 4a
conductivity on/off ratio~4040 dimensionlessVisual Estimate
Approximate
p004 · Results · Figure 4a

AC impedance hydroxide ion conductivity

NH2-UiO-66-100-OH · Pellet

Light on/off cycles at 55 deg C, 95% RH; visible light intensity 50 mW cm^-2.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet; cross-section 100 um x 3 mm; transport distance 300 um
Context
OH-loaded MOF pellet
Measurement source
p004 · Results · Figure 3d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hydroxide conductivity, light offMarked as a best value within this paper~8.5 x 10^-6 S cm^-10.00085 S m^-1Visual Estimate
Approximate
p004 · Results · Figure 3d; Figure 4a
hydroxide conductivity under visible light~1 x 10^-6 S cm^-10.0001 S m^-1Figure Axis
Approximate
p004 · Results · Figure 3d
conductivity on/off ratio~88 dimensionlessVisual Estimate
Approximate
p004 · Results · Figure 4a

AC impedance hydroxide ion conductivity

NH2-UiO-66-10-OH · Pellet

Light on/off cycles at 55 deg C, 95% RH; visible light intensity 50 mW cm^-2.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet; cross-section 100 um x 3 mm; transport distance 300 um
Context
OH-loaded MOF pellet
Measurement source
p004-p006 · Results; Methods · Figures 3b, 5a-b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
initial hydroxide conductivity, light off2 x 10^-6 S cm^-10.0002 S m^-1Text
Rounded Reported
p005 · Results · Figure 5a-b
hydroxide conductivity under visible light~2 x 10^-8 S cm^-10.000002 S m^-1Figure Axis
Approximate
p005 · Results · Figure 5a
conductivity on/off ratioMarked as a best value within this paper99.699.6 dimensionlessText
Exact Reported
p005 · Results · Figure 4b
on/off ratio after storage and cycling~70 after 10 cycles after more than 2 months70 dimensionlessText
Approximate
p005 · Results · Figure S14

AC impedance hydroxide ion conductivity

NH2-UiO-66-50-OH · Pellet

Light on/off cycles at 55 deg C, 95% RH; visible light intensity 50 mW cm^-2.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet; cross-section 100 um x 3 mm; transport distance 300 um
Context
OH-loaded MOF pellet
Measurement source
p004-p005 · Results · Figures 3c, 4b-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
hydroxide conductivity, light off~8 x 10^-6 S cm^-10.0008 S m^-1Visual Estimate
Approximate
p004 · Results · Figure 3c; Figure 4a
hydroxide conductivity under visible light~4.5 x 10^-7 S cm^-10.000045 S m^-1Figure Axis
Approximate
p004 · Results · Figure 3c
conductivity on/off ratio19.219.2 dimensionlessText
Exact Reported
p005 · Results · Figure 4b

AC impedance Nyquist plots under light-on/light-off cycling

NH2-UiO-66-10-OH · Pellet

Nyquist plots corresponding to Figure 3 for NH2-UiO-66-0-OH, -10-OH, -50-OH, and -100-OH at 55 deg C and 95% RH.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellets
Measurement source
p004 · Additional figures · Figure S4
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Nyquist response during light switchingNyquist arcs increase strongly under light on and recover under light off for the OH-loaded modulator seriesQualitative
Qualitative
p004 · Additional figures · Figure S4

AC impedance hydroxide conductivity under light-on/light-off cycling at varied relative humidity

NH2-UiO-66-10-OH · Pellet

NH2-UiO-66-10-OH at 55 deg C under 95, 85, 75, 65, and 55% RH.

Temperature
328
Atmosphere
55-95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p007-p008 · Additional figures · Figures S10-S11
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
RH-series on/off ratio at 55% RH~33 dimensionlessFigure Axis
Approximate
p007 · Additional figures · Figure S10e
RH-series on/off ratio at 65% RH~22 dimensionlessFigure Axis
Approximate
p007 · Additional figures · Figure S10d
RH-series on/off ratio at 75% RH~22 dimensionlessFigure Axis
Approximate
p007 · Additional figures · Figure S10c
RH-series on/off ratio at 85% RH~22 dimensionlessFigure Axis
Approximate
p007 · Additional figures · Figure S10b

AC impedance hydroxide conductivity under light-on/light-off cycling at varied relative humidity

NH2-UiO-66-50-OH · Pellet

NH2-UiO-66-50-OH at 55 deg C under 95, 85, 75, 65, and 55% RH.

Temperature
328
Atmosphere
55-95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p008-p009 · Additional figures · Figures S12-S13
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
RH-series on/off ratio at 55% RH~1.21.2 dimensionlessFigure Axis
Approximate
p008 · Additional figures · Figure S12e
RH-series on/off ratio at 65% RH~1.81.8 dimensionlessFigure Axis
Approximate
p008 · Additional figures · Figure S12d
RH-series on/off ratio at 75% RH~33 dimensionlessFigure Axis
Approximate
p008 · Additional figures · Figure S12c
RH-series on/off ratio at 85% RH~2.52.5 dimensionlessFigure Axis
Approximate
p008 · Additional figures · Figure S12b

AC impedance hydroxide conductivity cycling after storage

NH2-UiO-66-10-OH · Pellet

NH2-UiO-66-10-OH after being placed for two months; 55 deg C, 95% RH light-on/light-off cycles.

Temperature
328
Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet after storage
Measurement source
p009 · Additional figures · Figure S14
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
light-off conductivity after two-month storage cycling~1 x 10^-6 S cm^-1 peaks during repeated cycles0.0001 S m^-1Figure Axis
Approximate
p009 · Additional figures · Figure S14
light-on conductivity after two-month storage cycling~1.5 x 10^-8 S cm^-1 troughs during repeated cycles0.0000015 S m^-1Figure Axis
Approximate
p009 · Additional figures · Figure S14

AC impedance hydroxide conductivity under light-on/light-off cycling at varied temperature

NH2-UiO-66-10-OH · Pellet

NH2-UiO-66-10-OH at 45, 55, 65, 75, and 85 deg C under 95% RH.

Temperature
318-358
Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p005-p006 · Additional figures · Figures S6-S7
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
temperature-series on/off ratio at 45 deg C~22 dimensionlessFigure Axis
Approximate
p004-p005 · Results · Figure 4b; Figure S6a
temperature-series on/off ratio at 65 deg C~8080 dimensionlessFigure Axis
Approximate
p004-p005 · Results · Figure 4b; Figure S6c
temperature-series on/off ratio at 75 deg C~5555 dimensionlessFigure Axis
Approximate
p005 · Additional figures · Figure S6d
temperature-series on/off ratio at 85 deg C~2.52.5 dimensionlessFigure Axis
Approximate
p005 · Additional figures · Figure S6e

AC impedance hydroxide conductivity under light-on/light-off cycling at varied temperature

NH2-UiO-66-50-OH · Pellet

NH2-UiO-66-50-OH at 45, 55, 65, 75, and 85 deg C under 95% RH.

Temperature
318-358
Atmosphere
95% RH
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p006-p007 · Additional figures · Figures S8-S9
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
temperature-series on/off ratio at 45 deg C~1.41.4 dimensionlessFigure Axis
Approximate
p006 · Additional figures · Figure S8a
temperature-series on/off ratio at 65 deg C~1313 dimensionlessFigure Axis
Approximate
p006 · Additional figures · Figure S8c
temperature-series on/off ratio at 75 deg C~55 dimensionlessFigure Axis
Approximate
p006 · Additional figures · Figure S8d
temperature-series on/off ratio at 85 deg C~44 dimensionlessFigure Axis
Approximate
p006 · Additional figures · Figure S8e

AC impedance photoswitching under varied temperature and relative humidity

NH2-UiO-66-10-OH · Pellet

On/off ratio dependent on temperature under 95% RH and on RH at 55 deg C.

Atmosphere
varied RH; 95% RH for temperature series
Geometry
Ag-electroded pellet
Context
OH-loaded MOF pellet
Measurement source
p004-p005 · Results · Figure 4b-c
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
optimal photoswitch temperatureMarked as a best value within this paper55 deg C328.15 KText
Exact Reported
p005 · Results · Figure 4b
humidity reduction causing conductivity decline95% RH to 85% RHText
Qualitative
p005 · Results · Figure 4c