Resistive methanol gas sensing
Co-TCPP-Ac NS thin film-based sensor · Electrode
30% RH at 25 degC; exposed to methanol gas from 0.5 ppm to 100 ppm; ambient air carrier/recovery gas; response R = Ra/Rg.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Methanol response/recovery time at 100 ppm | 163 s / 7 s at 100 ppm | — | — | SI Table Exact Reported | 9 · Table S2 · Table S2 |
| Methanol response/recovery time at 20 ppmMarked as a best value within this paper | 6 s / 2 s at 20 ppm | — | — | Text Exact Reported | 1 · abstract · Fig. 3c |
| Methanol response/recovery time rangeMarked as a best value within this paper | from 6 s/2 s to 163 s/7 s over 0.5-100 ppm | — | — | Text Range | 3 · main text · Fig. 3c; Table S2 |
| Methanol response relative to formaldehyde | nearly 25 times that of formaldehyde | — | nearly | Text Approximate | 3 · main text · Fig. 3f |
| Methanol concentration test range | 0.5 ppm to 100 ppm | — | — | Text Range | 4-5 · Gas sensor characterizations · Fig. 3a |
| Theoretical limit of detection for methanolMarked as a best value within this paper | 100 ppb | 0.1 ppm | — | Text Rounded Reported | 3 · main text · Fig. 3b |
| Methanol response at 0.5 ppm | Ra/Rg = 1.3 at 0.5 ppm | — | — | Text Rounded Reported | 3 · main text · Fig. 3a |
| Methanol response at 100 ppmMarked as a best value within this paper | Ra/Rg = 363.2 at 100 ppm | — | — | Text Rounded Reported | 3 · main text · Fig. 3a; Tables S2-S3 |
| Stability/repeatability test duration | 30 days | 30 days | — | Text Exact Reported | 3 · main text · Fig. 3e; Fig. S6 |
| Working temperature in comparison table | 25 degC | 298.15 K | — | SI Table Exact Reported | 9 · Table S2 · Table S2 |