AC impedance with HOIKI-3532 LCR tester and custom fixture
A-PVDF-N@Nafion · Thin Film
PEM strips 3 x 1 cm; 30-80 C; 100% RH; average of multiple measurements
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| proton conductivity at 30 C | approximately 55.0 mS/cm at 30 C | — | — | Figure Axis Approximate | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity at 40 C | approximately 65.0 mS/cm at 40 C | — | — | Figure Axis Approximate | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity at 50 C | approximately 75.0 mS/cm at 50 C | — | — | Figure Axis Approximate | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity at 60 C | approximately 83.0 mS/cm at 60 C | — | — | Figure Axis Approximate | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity at 70 C | approximately 96.0 mS/cm at 70 C | — | — | Figure Axis Approximate | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity at 80 C and 100% RH | 109.89 mS/cm | — | — | Text Exact Reported | p005 / journal page 7326 · 3.2 Characterization of PVDF/UIO@Nafion · Figure 5a |
| proton conductivity enhancement versus PVDF@Nafion | 80.38% | — | — | Calculated From Reported Approximate | p001 / journal page 7322 · Abstract |