Other — Stabilization of NASICON-Type Electrolyte against Li Anode via an Ionic Conductive MOF-Incorporated Adhesive Interlayer

Measurement evidence

Other

Stabilization of NASICON-Type Electrolyte against Li Anode via an Ionic Conductive MOF-Incorporated Adhesive Interlayer · Zhao R., Gao L., Song M. et al. · ACS Energy Letters · 2021 · 3141-3150

1 measurement group · 2 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Differential scanning calorimetry (DSC)

ZCPL film/interlayer · Thin Film

PEO+LiTFSI and ZCPL melting behaviour

Geometry
polymer films
Context
MOF-polymer composite compared with MOF-free polymer
Measurement source
7 · Supplementary Figures · Figure S8
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
PEO+LiTFSI melting point68.8 CCaption
Exact Reported
7 · Supplementary Figures · Figure S8
ZCPL melting point64.7 CCaption
Exact Reported
7 · Supplementary Figures · Figure S8