X-ray diffraction (XRD)

as-synthesised Cu3(HHTP)2 powder · Powder

Pattern compared with simulated Cu3(HHTP)2 and reported characterisation.

Geometry
powder
Context
pristine conductive MOF
Measurement source
2 · 2. Results and Discussion · Figure 1a
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
XRD (004) broad peak position28 deg 2thetaText
Rounded Reported
2 · 2. Results and Discussion · Figure 1a
XRD (100) peak position4.7 deg 2thetaText
Rounded Reported
2 · 2. Results and Discussion · Figure 1a
XRD (200) peak position9.5 deg 2thetaText
Rounded Reported
2 · 2. Results and Discussion · Figure 1a
XRD (210) peak position12.8 deg 2thetaText
Rounded Reported