Sensing Application — Detection of Ascorbic Acid by Two-Dimensional Conductive Metal-Organic Framework-Based Electrochemical Sensors

Measurement evidence

Sensing Application

Detection of Ascorbic Acid by Two-Dimensional Conductive Metal-Organic Framework-Based Electrochemical Sensors · Wang S., Li P., Wang J. et al. · Molecules · 2024 · 2413

5 measurement groups · 36 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

differential pulse voltammetry (DPV)

Cu3(HHTP)2/SPE · Electrode

0.1 mol/L PBS; DPV range -1 to 1 V; potential increment 0.005 V; pulse amplitude 0.05 V; pulse width 0.3 s; AA concentration range 25-1645 umol/L.

Geometry
screen-printed electrode sensor
Context
Cu3(HHTP)2 composite electrode
Measurement source
5,8 · 2. Results and Discussion; 3.2.4. Electrochemical Test · Figure 4a,b
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
AA calibration R2R2 = 0.99Text
Exact Reported
5 · 2. Results and Discussion · Figure 4b
AA detection linear range upper boundMarked as a best value within this paper1645 umol/L1645 umol/LText
Exact Reported
5 · 2. Results and Discussion · Figure 4a,b
AA detection linear range lower boundMarked as a best value within this paper25 umol/L25 umol/LText
Exact Reported
5 · 2. Results and Discussion · Figure 4a,b
AA calibration slopey = -0.0345x - 2 x 10-6Text
Exact Reported
5 · 2. Results and Discussion · Figure 4b
AA detection limitMarked as a best value within this paper2.44 umol/L (S/N = 3)2.44 umol/LS/N = 3Text
Exact Reported
8 · 4. Conclusions · Figure 4a,b

parallel electrode uncertainty experiment

Cu3(HHTP)2/SPE · Electrode

Twelve Cu3(HHTP)2/SPE sensors prepared to detect AA; average current and electrode uncertainty calculated by guideline.

Geometry
screen-printed electrode sensor
Context
Cu3(HHTP)2 composite electrode reproducibility
Measurement source
1 · Supplementary Materials · Table S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
parallel sensor 1 oxidation peak current9.44 uA9.44 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 2 oxidation peak current10.80 uA10.8 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 3 oxidation peak current10.99 uA10.99 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 4 oxidation peak current11.10 uA11.1 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 5 oxidation peak current10.78 uA10.78 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 6 oxidation peak current10.70 uA10.7 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 7 oxidation peak current11.57 uA11.57 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 8 oxidation peak current10.32 uA10.32 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 9 oxidation peak current11.65 uA11.65 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 10 oxidation peak current10.50 uA10.5 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 11 oxidation peak current10.28 uA10.28 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor 12 oxidation peak current10.58 uA10.58 uASI Table
Exact Reported
1 · Supplementary Materials · Table S1
parallel sensor average currentI = 10.725 uA10.725 uACalculated From Reported
Exact Reported
8 · 3.2.6. Electrode Uncertainty Experiments · Table S1
electrode uncertaintyMarked as a best value within this paper0.171Text
Exact Reported
6 · 2. Results and Discussion · Table S1

DPV interference/selectivity test

Cu3(HHTP)2/SPE · Electrode

200 uM AA with 2 mM KCl, Glu, Gly, and CA, respectively; interferences are 10-times AA concentration.

Geometry
screen-printed electrode sensor
Context
Cu3(HHTP)2 composite electrode
Measurement source
5-6 · 2. Results and Discussion · Figure 4c,d; Figure S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
interference concentration2 mM interferences; 10-times interference2000 umol/LCaption
Exact Reported
6 · Figure 4 caption · Figure 4c,d
AA plus CA DPV signal relative to pure AA1.2 times higher than pure AAText
Exact Reported
5 · 2. Results and Discussion · Figure 4c,d
selectivity against Glu, KCl, and Glyalmost no change in DPV current responseText
Qualitative
5-6 · 2. Results and Discussion · Figure 4c,d

standard addition recovery in mouse serum

Cu3(HHTP)2/SPE · Electrode

Cu3(HHTP)2/SPE used to detect AA in actual mouse serum samples at 25, 55, and 285 umol/L.

Geometry
screen-printed electrode sensor
Context
Cu3(HHTP)2 composite electrode in biological sample application
Measurement source
6 · 2. Results and Discussion · Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
serum AA detected value at 25 umol/L24.7 umol/L24.7 umol/LTable
Exact Reported
6 · Table 1 · Table 1
serum AA recovery at 25 umol/L98.6%0.986 fractionTable
Exact Reported
6 · Table 1 · Table 1
serum AA RSD at 25 umol/L4.87%Table
Exact Reported
6 · Table 1 · Table 1
serum AA detected value at 285 umol/L282.2 umol/L282.2 umol/LTable
Exact Reported
6 · Table 1 · Table 1
serum AA recovery at 285 umol/LMarked as a best value within this paper99.0%0.99 fractionTable
Exact Reported
6 · Table 1 · Table 1
serum AA RSD at 285 umol/LMarked as a best value within this paper0.67%Table
Exact Reported
6 · Table 1 · Table 1
serum AA detected value at 55 umol/L53.9 umol/L53.9 umol/LTable
Exact Reported
6 · Table 1 · Table 1
serum AA recovery at 55 umol/L98.0%0.98 fractionTable
Exact Reported
6 · Table 1 · Table 1
serum AA RSD at 55 umol/L4.08%Table
Exact Reported
6 · Table 1 · Table 1

current retention over time

Cu3(HHTP)2/SPE · Electrode

AA response current of Cu3(HHTP)2/SPE evaluated over first, fifth, and tenth day in SI Figure S5; main text reports 86% retention after 5 days but appears to reference a non-present Figure S6.

Geometry
screen-printed electrode sensor
Context
Cu3(HHTP)2 composite electrode
Measurement source
3 · Figure S5 caption · Figure S5
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
AA response current on fifth dayabout 4.15 uA from SI Figure S5b bar4.15 uAVisual Estimate
Approximate
3 · Supplementary Materials · Figure S5b
AA response current on first dayMarked as a best value within this paperabout 4.35 uA from SI Figure S5b bar4.35 uAVisual Estimate
Approximate
3 · Supplementary Materials · Figure S5b
AA response current on tenth dayabout 3.75 uA from SI Figure S5b bar3.75 uAVisual Estimate
Approximate
3 · Supplementary Materials · Figure S5b
tenth-day current retention estimated from SI barsabout 86% of first-day current from Figure S5b bars0.86 fractionCalculated From Reported
Approximate
3 · Supplementary Materials · Figure S5b
5-day current retentionMarked as a best value within this paper86% of initial current after 5 days0.86 fractionText
Exact Reported
6 · 2. Results and Discussion · Figure S5/S6 inconsistency