Porosity — Detection of Ascorbic Acid by Two-Dimensional Conductive Metal-Organic Framework-Based Electrochemical Sensors

Measurement evidence

Porosity

Detection of Ascorbic Acid by Two-Dimensional Conductive Metal-Organic Framework-Based Electrochemical Sensors · Wang S., Li P., Wang J. et al. · Molecules · 2024 · 2413

1 measurement group · 3 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

N2 adsorption-desorption and BET analysis

as-synthesised Cu3(HHTP)2 powder · Powder

N2 isotherms measured at 77 K; samples degassed under vacuum at 100 C for 12 h before testing.

Temperature
77
Atmosphere
N2
Geometry
powder
Context
pristine conductive MOF
Measurement source
2 · 2. Results and Discussion · Figure 1d; Figure S1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
average pore diameterMarked as a best value within this paperabout 1.4 nmText
Approximate
2 · 2. Results and Discussion · Figure S1
BET specific surface areaMarked as a best value within this paper236 m2 g-1236 m2/gText
Exact Reported
2 · 2. Results and Discussion · Figure 1d
N2 isotherm typeType I isotherm; microporousText
Qualitative
2 · 2. Results and Discussion · Figure 1d