Solution conductivity measurement
Ni3(HITP)2@PDA nanoparticles · Powder
Conductivity of Ni3(HITP)2@PDA aqueous dispersions at increasing concentration, read from Fig. 2i.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Ni3(HITP)2@PDA conductivity at 0 ug/mL | approximately 1 uS/cm from Fig. 2i | — | — | Figure Axis Approximate | 2023 · 3.3 Characterization of conductive MOF · Fig. 2i |
| Ni3(HITP)2@PDA conductivity at 1000 ug/mLMarked as a best value within this paper | approximately 58 uS/cm from Fig. 2i | — | — | Figure Axis Approximate | 2023 · 3.3 Characterization of conductive MOF · Fig. 2i |
| Ni3(HITP)2@PDA conductivity at 125 ug/mL | approximately 7 uS/cm from Fig. 2i | — | — | Figure Axis Approximate | 2023 · 3.3 Characterization of conductive MOF · Fig. 2i |
| Ni3(HITP)2@PDA conductivity at 250 ug/mL | approximately 15 uS/cm from Fig. 2i | — | — | Figure Axis Approximate | 2023 · 3.3 Characterization of conductive MOF · Fig. 2i |
| Ni3(HITP)2@PDA conductivity at 500 ug/mL | approximately 31 uS/cm from Fig. 2i | — | — | Figure Axis Approximate | 2023 · 3.3 Characterization of conductive MOF · Fig. 2i |