Other — Enhancing pancreatic cancer ablation efficiency: bipolar IRE with conductive MOF

Measurement evidence

Other

Enhancing pancreatic cancer ablation efficiency: bipolar IRE with conductive MOF · Xu L., Lou W., Xu F. et al. · Materials Chemistry Frontiers · 2025 · 2018-2030

6 measurement groups · 11 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

CCK-8 cytotoxicity and haemolysis assay

Ni3(HITP)2@PDA nanoparticles · Powder

KPC/L929 cell viability after 12 and 24 h exposure and blood haemolysis at nanoparticle concentrations up to 200 ug/mL.

Temperature
310
Atmosphere
cell/blood assay
Context
Composite sample biosafety.
Measurement source
2023 · 3.4 Biosafety of Ni3(HITP)2@PDA · Fig. 3; Fig. S16
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
No significant cytotoxicity below 100 ug/mLno significant cytotoxicity at concentrations below 100 ug mL^-1 (P > 0.05)thresholdText
Qualitative
2023 · 3.4 Biosafety · Fig. 3a; Fig. S16a
Haemolysis below 3% under 200 ug/mLhemolysis rate below 3% at concentrations under 200 ug mL^-1upper boundText
Approximate
2023 · 3.4 Biosafety · Fig. 3b; Fig. S16b

Dynamic light scattering

Ni3(HITP)2@PDA nanoparticles · Powder

PDI and hydrodynamic size measurement of pristine Ni3(HITP)2 and Ni3(HITP)2@PDA.

Atmosphere
solution
Context
Pristine versus PDA-modified particles.
Measurement source
2022 · 3.3 Characterization of conductive MOF · Fig. 2h; Fig. S11
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni3(HITP)2@PDA particle diameter426.90 +/- 7.18 nm+/- 7.18 nmText
Exact Reported
2022 · 3.3 Characterization of conductive MOF · Fig. 2h
Ni3(HITP)2@PDA PDIMarked as a best value within this paper0.4318 +/- 0.02+/- 0.02Text
Exact Reported
2022 · 3.3 Characterization of conductive MOF · Fig. S11
Pristine Ni3(HITP)2 PDI0.4878 +/- 0.04+/- 0.04Text
Exact Reported
2022 · 3.3 Characterization of conductive MOF · Fig. S11

Flow cytometry apoptosis assay

Bipolar IRE + Ni3(HITP)2@PDA treated KPC/tumour model · Model

KPC cell apoptosis after monopolar, bipolar, and bipolar + Ni3(HITP)2@PDA IRE treatments.

Atmosphere
cell culture
Geometry
Monopolar 1500 V cm^-1, 90 us, 90 pulses; bipolar 2500 V cm^-1, 90 us, 90 pulses.
Context
Application model with conductive MOF composite.
Measurement source
2025-2026 · 3.5 In vitro therapeutic mechanism · Fig. 4b; Fig. S19
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Bipolar IRE apoptosis rate45.52 +/- 1.83%+/- 1.83%Text
Exact Reported
2025 · 3.5 In vitro therapeutic mechanism · Fig. 4b; Fig. S19
Bipolar IRE + Ni3(HITP)2@PDA apoptosis rateMarked as a best value within this paper59.95 +/- 2.41%+/- 2.41%Text
Exact Reported
2025 · 3.5 In vitro therapeutic mechanism · Fig. 4b; Fig. S19

Murine subcutaneous KPC tumour response

Bipolar IRE + Ni3(HITP)2@PDA treated KPC/tumour model · Model

Tumour volume, tumour weight, body weight and histology over 14 days after bipolar IRE with local Ni3(HITP)2@PDA injection.

Atmosphere
in vivo
Geometry
100 uL Ni3(HITP)2@PDA injected 2 h before bipolar IRE; 2500 V cm^-1, 90 us, 90 pulses.
Context
Application model with conductive MOF composite.
Measurement source
2025-2027 · 3.6 In vivo therapeutic efficacy · Fig. 5; Fig. S20-S22
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Body weight stability during 14-day in vivo studyBody weight remained stable across all groups, with no significant differencesText
Qualitative
2025 · 3.6 In vivo therapeutic efficacy · Fig. 5c
In vivo tumour-volume reductionMarked as a best value within this paper85.77% +/- 0.21 reduction in tumor volume+/- 0.21%Text
Exact Reported
2025 · 3.6 In vivo therapeutic efficacy · Fig. 5b; Fig. S20

Potato model IRE ablation area

Bipolar IRE + Ni3(HITP)2@PDA treated KPC/tumour model · Model

Bipolar electrode ablation zone at 2500 V cm^-1 measured 24 h post-experiment.

Geometry
Bipolar and monopolar electrodes inserted along potato length; minimum insertion depth 10 mm.
Context
Application model; electrode ablation benchmark.
Measurement source
2022 · 3.2 In vitro therapeutic efficacy · Fig. S6
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Bipolar-electrode potato ablation area at 2500 V cm^-12.88 +/- 0.08 cm2+/- 0.08 cm2Text
Exact Reported
2022 · 3.2 In vitro therapeutic efficacy · Fig. S6

Zeta potential

Ni3(HITP)2@PDA nanoparticles · Powder

Solution stability assessment of Ni3(HITP)2@PDA.

Atmosphere
solution
Context
Composite sample.
Measurement source
2022 · 3.3 Characterization of conductive MOF · Fig. S13
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
Ni3(HITP)2@PDA zeta potential-31.71 +/- 2.75 mV+/- 2.75 mVText
Exact Reported
2022 · 3.3 Characterization of conductive MOF · Fig. S13