Spectroscopy — Chemical sensors based on ionically conductive metal-organic frameworks for selective cadaverine detection

Measurement evidence

Spectroscopy

Chemical sensors based on ionically conductive metal-organic frameworks for selective cadaverine detection · Zhang S., Li L., Lu Y. et al. · Journal of Materials Chemistry C · 2022 · 5497-5504

2 measurement groups · 9 results

Reported values remain attached to the sample, method, conditions, extraction quality and source location that produced them.

Fourier transform infrared spectroscopy (FT-IR)

IC-CuTHPP thin-film sensor on ITO interdigital electrode · Electrode

CuTHPP-MOF film compared with H2THPP ligand.

Geometry
Thin film
Context
pristine CuTHPP framework formation
Measurement source
main p.2, article p.5498 · Results and discussion · Fig. 1d
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
H2THPP N-H stretching vibration3322 cm-1Text
Exact Reported
main p.2, article p.5498 · Results and discussion · Fig. 1d
N-H peak disappearance in CuTHPP-MOFN-H stretching peak disappeared in MOF spectrumText
Qualitative
main p.3, article p.5499 · Results and discussion · Fig. 1d

X-ray photoelectron spectroscopy (XPS)

IC-CuTHPP thin-film sensor after cadaverine exposure · Electrode

Elemental composition and N 1s spectra of CuTHPP-MOF before and after cadaverine detection.

Geometry
CuTHPP thin-film sensor
Context
pristine versus cadaverine-exposed CuTHPP
Measurement source
main p.3-p.4, article pp.5499-5500 · Results and discussion · Fig. 3c,d; Table 1
PropertyReported valueNormalised valueUncertaintyOrigin and qualitySource
N 1s C-N=C binding energy400 eVText
Exact Reported
main p.3, article p.5499 · Results and discussion · Fig. 3c,d
N 1s C-N-H binding energy402 eVText
Exact Reported
main p.3, article p.5499 · Results and discussion · Fig. 3c,d
Cu percentage after cadaverine detection3.56%Table
Exact Reported
main p.4, article p.5500 · Results and discussion · Table 1
Cu percentage before cadaverine detection3.56%Table
Exact Reported
main p.4, article p.5500 · Results and discussion · Table 1
N percentage after cadaverine detection12.11%Table
Exact Reported
main p.4, article p.5500 · Results and discussion · Table 1
N percentage before cadaverine detection8.82%Table
Exact Reported
main p.4, article p.5500 · Results and discussion · Table 1
N 1s N-Cu binding energy398.4 eVText
Exact Reported
main p.3, article p.5499 · Results and discussion · Fig. 3c,d