time-dependent Cu 2p XPS deconvolution
Air-exposed Cu3(HITT)2 · Unknown
High-resolution Cu 2p XPS after ambient air exposure from pristine to 83 days.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| Cu2+/Cu+ ratio after 14 days | 1.64 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 1 day | 0.76 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 30 days | 4.31 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 45 days | 7.26 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 4 days | 1.32 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 73 days | 7.77 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| Cu2+/Cu+ ratio after 83 daysMarked as a best value within this paper | 8.25 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |
| pristine Cu2+/Cu+ ratio | 0.66 | — | — | Figure Axis Rounded Reported | 20505 · Figure 5b · Figure 5b |