Four-probe electrical conductivity
Pressed-disc Cu3(HHTP)2 for four-probe conductivity · Pellet
RTS-8 four-point probe; powder pressed into discs.
| Property | Reported value | Normalised value | Uncertainty | Origin and quality | Source |
|---|---|---|---|---|---|
| electrical conductivity | 0.47 ± 0.12 S m-1 | — | ± 0.12 | Text Exact Reported | 4 · Section 2.2 · Figure S15 |